background image

LAN Configuration

3

3

After the datalogger is connected to the router 
through the network cable,LAN Configuration is 
completed.

NOTE

WL Stick automatically obtains IP by default and 
and connects to the network. If the datalogger fails 
to connect to the network, please perform the 
following steps to set the IP address. Otherwise, 
skip the following steps.

Step 1: The wireless device(mobile phone or laptop) 
connects to the datalogger hotspot(Solis_serial 
number). The default password is 

 

123456789.

Summary of Contents for S2-WL-ST

Page 1: ...WL Stick Datalogger Quick Installation Manual Version 1 2 1 Quick Installation Manual 1 WL stick Delivery Content ...

Page 2: ...amp Claw Step4 Connect the RJ45 Plug to the datalogger and tighten the Plastic Nut To router Plastic Nut Thread Clamp Claw Sealing Ring RJ45 Plug Ethernet Port Due to limited space only RJ45 plug without protective shell can be used NOTE The diameter of the network cable connection end on the data logger is about 3 5mm after it is completely fastened The network cable is required to be circular or...

Page 3: ... example Please follow the instructions below Match the joint 1 2 Install the datalogger Install the datalogger Step 1 Match the joint and then insert the datalogger to the inverter COM port Step 2 Rotate the black ring in clockwise Only rotate the black ring at the connection end not rotate the main body NOTE 2 1 ...

Page 4: ...f the inverter is 01 and each inverter on the communica tion circuit needs to be assigned with different slave address different slave address like 01 02 03 04 NOTE The device must be installed away from the strong magnetic field produced by large electrical appliances such as microwave oven refrigerator telephone metal walls etc Otherwise the communication quality may be affected It may also be a...

Page 5: ...tween the datalogger and the server Shows the connection status between datalogger and the inverter Shows the power supply status of the datalogger LED Lights Status Internet Indicators NET Inverter COM Indicators Power Indicator COM PWR The button on the front is used for RESET connection Short press will send the data immediately Long press for over 10 seconds until only the red light is on will...

Page 6: ...omatically obtains IP by default and and connects to the network If the datalogger fails to connect to the network please perform the following steps to set the IP address Otherwise skip the following steps Step 1 The wireless device mobile phone or laptop connects to the datalogger hotspot Solis_serial number The default password is 123456789 ...

Page 7: ...nd Password Admin 123456789 Save Step 3 Select the and WAN port setting Static IP Enter IP address Subnet mask Gateway address DNS server address for network cable Then click Save Step 4 The following interface pops up to indicate that the setting is successful Otherwise please try LAN configuration again ...

Page 8: ...or Google Play Store by searching Solis Cloud Step 2 If it is a new datalogger please configure it first then click the WiFi Configuration Unlogged account click on More Tools and select WiFi Configuration More Tools If you have logged in please click Tool to enter WiFi Configuration Tool Solis Cloud WiFi Configuration 4 4 ...

Page 9: ...Step 4 Choose the configuration method recommended click Browser Configuration Step 3 Manually input datalogger SN or Scan the SN on the datalogger Input datalogger SN ...

Page 10: ...Step 5 Make sure that the green light flashes at intervals then click the I m sure it is flashing ...

Page 11: ...Step 6 Connect to the datalogger hotspot Solis_serial number Step 7 The default password is 123456789 After that return to APP ...

Page 12: ...Step 8 Click make sure the phone is connected to router WiFi and switch back to the page to fill in the WiFi password then move to next step Step 9 Configuration Complete ...

Page 13: ...ep 1 The wireless device mobile phone or laptop connects to the datalogger hotspot Solis_serial number The default password is 123456789 Step 2 Enter in the web browser 10 10 100 254 when the router is not connected open the following configuration interface Enter Username and Password admin 123456789 Step 3 Select the enter the new Advanced password and then click the Save ...

Page 14: ...Step2 Select Owner or Organization for email address registration Create the Solis Cloud Account 6 6 Step 1 Click the Register Register ...

Page 15: ...Step3 Enter the email to get the verification code than enter your account and password last click the Register Owner Register Register ...

Page 16: ...Organization Register ...

Page 17: ...Create Plant Step1 Enter the main page of Solis Cloud APP click at the top right corner and select Add plant 7 7 Add plant ...

Page 18: ...Step 2 Input the information of the plant as required Then click Done Done ...

Page 19: ...the plant information Click Create plant Step 4 Click to enter the plant View plant homepage then add the datalogger View plant Add UTC 12 00 Sun Line West Create plant Plant Address Ningbo Ginlong Technologies Co Ltd ...

Page 20: ...Scan datalogger SN Barcode Can t find barcode Manual input Step 5 Scan the SN number of the datalogger or manually input it Note Scan the NOT the datalogger SN inverter SN ...

Page 21: ...Continu atalogger View Plant Step 6 Plant creation succeeds Click to check the monitoring data If Continu atalogger the plant has multiple dataloggers please click View Plant ...

Page 22: ...nd if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the ...

Page 23: ...e provide the following information as well Inverter SN Datalogger SN Problem Description Ginlong Technologies Co Ltd No 57 Jintong Road Binhai Industrial Park Xiangshan Ningbo Zhejiang 315712 P R China Tel 86 0 574 6578 1806 Fax 86 0 574 6578 1606 Email info ginlong com Web www ginlong com ...