background image

 

 

 

   
 

 

 

 

 
 
 
 
 
 

Sollae Systems Co., Ltd. 

http://www.ezTCP.com 

 

1port Remote I/O Controller 
(dry / wet contact support) 

CIE-H12 User Manual 

Version 1.9 
 

Summary of Contents for CIE-H12

Page 1: ...Sollae Systems Co Ltd http www ezTCP com 1port Remote I O Controller dry wet contact support CIE H12 User Manual Version 1 9 ...

Page 2: ...cal and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences to the environment and human health which could otherwise be caused by inappropriate disposal of this product The recycling of materials will help to conserve natural resources For more detailed information about the recycling of this product please contact your loca...

Page 3: ...1 1 6 4 Power 11 1 6 5 System LED 12 1 6 6 ISP Switch 12 2 Installation and Test 13 2 1 Installation 13 2 1 1 Setting Network Aera 13 2 2 Test operation 15 2 2 1 Modbus TCP Test 15 2 2 2 HTTP Test with a WEB browser 17 3 Configuration 18 3 1 Configuration with ezManager 18 3 1 1 Configuration via LAN 18 4 Operation Modes 19 4 1 What is the Operation Mode 19 4 2 How to change the mode to another 19...

Page 4: ...ling on Web HTTP 26 5 3 1 Changing port number for HTTP 26 5 3 2 Uploading Users Webpage 27 6 System Management 28 6 1 Upgrading Firmware 28 6 1 1 Firmware 28 6 1 2 Processes 28 6 2 Changing Homepage 30 6 2 1 Webpage 30 6 2 2 Processes 30 6 3 Status Monitoring 33 6 3 1 Using TELNET 33 6 3 2 Checking status by ezManager 35 7 Additional Functions 37 7 1 Security 37 7 1 1 Restriction of Access ezTCP ...

Page 5: ...over Modbus TCP 45 9 Related material 46 9 1 Technical Documents 46 9 2 Smart phone application 46 10 Technical Support and Warranty 47 10 1Technical Support 47 10 2Warranty 47 10 2 1 Refund 47 10 2 2 Free Repair Services 47 10 2 3 Charged Repair Services 47 11 Precaution and Exemption from Liability 48 11 1Precaution 48 11 2Exemption from Liability 49 11 2 1 English version 49 11 2 2 French versi...

Page 6: ...ls the relay outputs HTTP Modbus TCP and Macro mode can be used for these functions CIE H12 has two input ports and one output port One of the input ports is a dry contact type and the other one is wet contact Thus you are allowed to use it under both types of systems 1 2 Features Remote I O controller 2 Digital Input ports Dry contact 1 port Wet contact 1 port 1 Digital Output Port Relay interfac...

Page 7: ...H12 User Manual Ver 1 9 6 http www ezTCP com 1 3 Application Examples remote I O device server Figure 1 1 remote I O device server Internet Switch Figure 1 2 internet switch Macro mode Figure 1 3 macro mode ...

Page 8: ...ase TX Auto Sensing Auto MDI MDIX Cable Auto sensing Temperature Operate 0 70 Storage 40 85 Certification CE KC Environment Follows Europe RoHS Directive Table 1 1 H W specification 1 5 2 S W specification Protocol TCP UDP IP ICMP ARP DHCP DNS lookup DDNS Modbus TCP HTTP SMTP Diagnose Online Debugging Function Operation mode Normal Normal communication mode ISP F W upgrade Communicati on Mode I O ...

Page 9: ...put ports the front view In the front panel the DRY IN 0 port is the dry contact type and the WET IN 1 port is the wet contact type The switch input type Dry contact The first input port is a dry contact type so you can give the input signal by a switch Basically this port is the same with the port WET IN 1 but has additional part for dry contact Just use a switch for giving signal to this port Fi...

Page 10: ...about the polarity The circuit diagram of the input port is shown in the figure below Figure 1 7 a circuit diagram of the input port The voltage specification of the input port is as follows Over 1 8V H 1 Under 1 2V L 0 Max Input Voltage DC 24V Polarity Auto Polarity Table 1 3 the voltage specification of the input ports Use a shaped screwdriver to connect it with users devices since the output po...

Page 11: ...g Value Relay contact 0 OFF open 1 ON short Table 1 4 values of the output port The allowed output ports electrical current of voltage conditions are as in the following Voltage Condition Allowed current DC28V 5A Table 1 5 voltage conditions of the output port Use a shaped screwdriver to connect it with users devices since the output ports are interfaced with a 3 5mm terminal block CIE H12 is most...

Page 12: ...ernet It also provides auto MDI MDIX function that can automatically sense a 1 1 cable or cross over cable Each Ethernet device has its own hardware address MAC address CIE H12 is shipped to the market with the hardware address set in the factory Figure 1 10 the RJ45 connector 1 6 4 Power DC 5V is used for the power The specification of the power jack is as following Figure 1 11 the power specific...

Page 13: ...a connection on a network blinks transferring or receiving network data Front panel DI Yellow On when input ports signal is ON DO Green On when the output port s signal is ON Table 1 6 status of the system LED 1 6 6 ISP Switch There is an ISP switch located on the side of the product This button is for changing the mode to the ISP mode If you press it over a second or supply power while pressing i...

Page 14: ...et port to a PC It will be no problem if the Ethernet connection is established through network hubs Figure 2 1 the connection between CIE H12 and a PC 2 1 1 Setting Network Aera This step is for setting both CIE H12 and your PC to be located on the same network to establish a TCP connection Setting of the PC Add or change the IP address of the network adapter on your PC Click Windows Control Pane...

Page 15: ...per values should be set via ezManager Default values of some major parameters are listed on the table below To do the following simple test keep these values during the test Parameters Values Network Local IP Address 10 1 0 1 Subnet Mask 255 0 0 0 Option Telnet Checked IP Address Search Checked I O Port Web HTTP Checked Web HTTP Port 80 Modbus TCP Checked Master Slave Slave Connection Mode Passiv...

Page 16: ... can see the window as shown below Figure 2 3 Modbus TCP test program of the ezManager Search connected CIE H12 with Search All button Select a MAC address of searched product on the search result Check the Advanced Menu option Press the Modbus TCP button The test program will appear on the right side of the ezManager In the case of using previous versions of firmware than 3 1F the test program is...

Page 17: ...nput the local port for Modbus TCP of CIE H12 In a local area network and steps can be omitted Try to connect by pressing Connect button Then check if the input LEDs are turned on or off with signal input Check if the output LED is turned on or off with clicking the LEDs Click the Disconnect button after the test is completed ...

Page 18: ... HTTP test Input the IP address of your CIE H12 on the address field Ex 10 1 0 1 Check if the input LEDs are turned on or off with HIGH signal Check if the output LED is turned on or off with clicking the each of LEDs Press the Read button to update the status The way to control output ports manually On Off Pulse Parameter o0 Lower case p0 Lower case Value ON OFF Time ms 1 0 1 10000 Example http 1...

Page 19: ...ial appearance of ezManager 3 1 1 Configuration via LAN Checklists Make sure of the connection between your PC and CIE H12 via Ethernet If they are in the same network MAC Address search button can be used Otherwise only IP Address search is allowed to use Procedures Figure 3 2 procedures for configuration via LAN ...

Page 20: ...s mode is for normal data communication and has 2 communication modes Configuring parameters is also available in this mode ISP mode This mode is for upgrading firmware and HTML files In addition you can set environmental parameters even though the security options are activated You can also reset the security options 4 2 How to change the mode to another Figure 4 1 how to initiate each operation ...

Page 21: ...n automatically control the output ports by setting MACRO using some basic formula of Boolean Algebra Users can not control the output ports through HTTP or Modbus TCP WEB HTTP Users can monitor and control CIE H12 via HTTP Table 4 2 digital I O control types 4 5 ISP mode 4 5 1 Upgrading Firmware ISP mode is for upgrading firmware Upgrading Firmware is implemented by ezManager For more details abo...

Page 22: ...nnection Active Connection requesting a Modbus TCP connection Multiple Connection The numbers for multiple Modbus TCP connections Control Method of FC XX Control method for the output ports of the slave Single Multiple Control Method of AND OR Control method for the output ports of the master AND OR Peer Address Peer s IP address when CIE H12 performs active connections Peer Port Peer s local port...

Page 23: ...ut Port Base Address 5 1 3 Modbus TCP Master Mode In this mode CIE H12 operates as a Modbus TCP master As a master CIE H12 transmits its input information to the salve and outputs the slave s input value to its output port after reading the value periodically At this time CIE H12 controls the output ports with not only bit unit individually but also word unit at once FC 16 Multiple ports CIE H12 c...

Page 24: ...iple connections up to 8 hosts can be connected The active connection CIE H12 tries to establish a connection to the remote host The IP address or host name and port number of the remote host is required Table 5 3 the passive active connection 5 1 5 Initial Output Value The initial value of CIE H12 s output port can be configured The output ports are set to ON or OFF according to the value of Init...

Page 25: ...sis NOT AND OR Each operator is represented by the following symbols Name Sign Description Parenthesis Since calculations within the parenthesis have the highest priority they will be calculated first Nested parentheses are allowed NOT An operand that follows a NOT operator is toggled If an operand is 0 it will be changed to 1 If it is 1 it will be changed to 0 AND If both operand values surroundi...

Page 26: ... Input Port Equations Description Do0 A i0 i1 Perform bit OR i0 and i1 Do0 B i0 i1 Perform bit AND i0 and i1 Then toggle the result Table 5 5 an example of equation The following is the output values coming out as a result of expressions of input values Input ports Output port i0 i1 Do0 A Do0 B 0 0 0 1 0 1 1 1 1 0 1 1 1 1 1 0 Table 5 6 the logic table of the table 5 5 ...

Page 27: ... a password User name is not required Leave blank or put a random name Password should be the same with a password which is set through the ezManager 5 3 1 Changing port number for HTTP In case you cannot use the port number 80 default port number for HTTP because the ISP Internet Service Provider blocks the port you can change that port number Figure 5 2 changing port number for HTTP Input a port...

Page 28: ...possible to monitor and control the I O ports with your webpage made by yourself Upgrading HTML files CIE H12 has a default webpage when it is manufactured in the factory For advanced users we have been offering some examples sample web pages based on various technologies such as CSS and J query Figure 5 3 examples of webpage Default image based advanced CSS Jquery Text based ...

Page 29: ...ware file We update our homepage when a new firmware is released You can find it on our website Entering ISP mode Enter ISP mode to download firmware file to CIE H12 Run a TFTP client and ready to send the F W file Run a TFTP client program ezManager is equipped with the client program Click the Change F W HTML button Figure 6 1 running TFTP client Check the Advanced Menu check box Click the Chang...

Page 30: ...anual Ver 1 9 29 http www ezTCP com Checking firmware file and Sending Figure 6 2 sending firmware file Check if the name and path of the firmware file are correct Click the Send button Confirm the completed message ...

Page 31: ...TTP 6 2 2 Processes Making Users homepage or Downloading sample files Make your own homepage file or use sample homepage files freely available to download at our web site Entering ISP mode Enter ISP mode to send HTML files to CIE H12 Writing Web HTTP port number and selecting size of Web HTTP Figure 6 3 Web Basic Settings 80KB or 96KB for the Size of Web HTTP is allowed ...

Page 32: ... equipped with the client program Click the Change F W HTML button Figure 6 4 running TFTP client Check the Advanced Menu check box Click the Change F W HTML button to run TFTP client Select the Change HTML radio button Input the IP address of CIE H12 to the Local IP Address text box Press the Open Firmware HTML button and choose the HTML file ...

Page 33: ...l Ver 1 9 32 http www ezTCP com Checking files and Sending Figure 6 5 sending firmware file Check if the name and path of the html file including all images are correct Click the Send button Confirm the completed message ...

Page 34: ...t users should input the password After that messages from CIE H12 appear as shown in the figure below Figure 6 6 log in to CIE H12 on TELNET You can check multiple states with the following commands command option description usage st net Network Status lsh st net uptime System Uptime lsh st uptime sc OP1 OP2 Session Control lsh sc com1 close Table 6 1 Commands for checking states ...

Page 35: ...essions Figure 6 7 st net command st uptime st uptime command shows amount of time since CIE H12 has booted up Figure 6 8 st uptime command sc sc command is used when users close a session OP1 means the name of session and OP2 should be CLOSE Figure 6 9 sc command Lower case letters are only allowed to use sc command ...

Page 36: ... the status is automatically updated in every second Figure 6 10 status window of ezManager FIRMWARE VERSION The name of model and the version of firmware are displayed here SYSTEM UPTIME Operating time of CIE H12 is displayed since it boots up IP4 NETWORK INFORMATION All information about related items with IP Address including the MAC address is shown here It works even if the IP address is assi...

Page 37: ... MAC address is automatically stored in the ARP table This information is held for 1 minute If there is no data communication for 1 minute the information will be removed Notify Ports Change IOTRAP STATE This part shows E mail address what you entered when you use the function Notify Input or Output Port Change TCP IP Connection In this section the same information with TCP STATE is displayed with...

Page 38: ...xamples IP address network mask allowed IP address range 10 1 0 1 255 0 0 0 10 1 0 1 10 255 255 254 10 1 0 1 255 255 255 0 10 1 0 1 10 1 0 254 192 168 1 4 255 255 255 255 192 168 1 4 Table 7 1 examples of defining allowed IP range Apply to ezManager Apply to ezManager is for applying above two restrictions to ezManager functions like Search Read Write etc 7 1 2 Setting Password A password can be u...

Page 39: ... create host names on the website of DynDNS before use this All about service usage of an account could be changed according to the policy of DynDNS Homepage of DynDNS http dyn com dns Figure 7 1 setting DDNS Select the DDNS dyndns org item 40 320 is a fixed value Input the ID of DDNS account Input the password of the account Input one of the host names which you created on your account TCP UDP In...

Page 40: ...n receive debugging messages from CIE H12 on the network When you are facing a problem about the TCP connection or data communication use this function and send us the stored file We can use it for finding out the reason of your problem Debugging messages are broadcasted to entire network via UDP so it might cause serious network traffic Remember you should turn the option off after using it Setti...

Page 41: ...sages from CIE H12 over the network Auto update to display the latest captured file on the screen of MAC Address Information of a selected message Unavailable ⓐ To start capturing debugging messages from CIE H12 ⓑ To stop capturing debugging messages from CIE H12 ⓒ Unavailable ⓓ Load Message is for loading a debugging log file to display ⓔ Closing debugging message window ...

Page 42: ... Change When input or output port is changed you can receive an email for notification from CIE H12 using SMTP protocol When ports you selected are changed status of CIE H12 is sent to the Email address you entered Figure 7 4 Notify Input or Output Port Change Figure 7 5 I O port status notification email ...

Page 43: ...ever because the accuracy is only guaranteed in 10ms the designated values are rounded down in units of 10ms 7 3 3 Delay Output values are reflected to CIE H12 s output ports later than the time set to Delay For example if Delay is set to 0 the output values are reflected to the output ports immediately Although it is allowed to set the values in 1ms it is accurate to 10ms rounded down If the time...

Page 44: ...e firewall functions so it can cause some trouble to search CIE H12 Close or pause these programs before searching the product Stable supply of the power Check if the power is supplied continually If the power is constantly supplied the LED on RJ45 Orange of CIE H12 blinks slowly Connection with the network Make sure that the network connection is fine including Ethernet cable In this step we reco...

Page 45: ...the access may be denied by their firewall Under this circumstance users should ask the person in charge of their network to release ports which will be used Ex TCP 502 UDP 50005 Operation Mode A TCP connection is not possible when CIE H12 is operating in the ISP or Serial Configuration mode Connection Mode To make a TCP connection both a server passive mode and a client active mode should exist I...

Page 46: ...lated parameters that Unit ID Input Port Base Address Output Port Base Address Poll Interval and Notify Input change Checking which mode is using In case of MACRO or serialized Modbus TCP you can control the outputs of CIE H12 Turn the mode off if those modes are using Contact us if you have any questions about above steps or our products ...

Page 47: ...cuments You can find the following technical documents at our website Datasheet Modbus TCP protocol Combinations of I O Controllers Digital Pulse Output IP Change Notification DDNS Modmap Users manual etc 9 2 Smart phone application ezManager iOS ezManager Android TCP IP Client Android ...

Page 48: ... customer s request to refund the product within two weeks after purchase Sollae Systems will refund the product 10 2 2 Free Repair Services For product failures occurring within 2 years after purchase Sollae Systems provides free repair services or exchange the product However if the product failure is due to user s fault repair service fees will be charged or the product will be replaced at user...

Page 49: ...d applications provided by Sollae Systems for purposes other than those for which they were designed is prohibited Do not use the product in an extremely cold or hot place or in a place where vibration is severe Do not use the product in an environment in which humidity is high or a lot of oil exists Do not use the product where there is caustic or combustible gas Sollae Systems does not guarantee...

Page 50: ...ancial losses damage to property personal injury or the death of people or animals If you use the CIE H12 voluntarily or involuntarily for such unauthorized applications you agree to subtract Sollae Systems Co Ltd and its distributors from all liability for any claim for compensation Sollae Systems Co Ltd and its distributors entire liability and your exclusive remedy shall be Sollae Systems Co Lt...

Page 51: ...soit voiture camion train avion etc ni en milieu explosif ni dans des enceintes nucléaires ni dans des ascenseurs ni dans des aéroports ni dans des enceintes hospitaliers ni pour des applications à caractère médical ni dans des dispositifs de détection et d alerte anti intrusion ni dans des dispositifs de détection et d alerte anti incendie ni dans des dispositifs d alarme GTC ni pour des applicat...

Page 52: ...lectroniques usagés Le symbole de la poubelle barré présent sur le boîtier CIE H12 indique que vous ne pouvez pas vous débarrasser de ce dernier de la même façon que vos déchets courants Au contraire vous êtes responsable de l évacuation du boîtier CIE H12 lorsqu il arrive en fin de vie ou qu il est hors d usage et à cet effet vous êtes tenu de le remettre à un point de collecte agréé pour le recy...

Page 53: ...dation for a high capacity relay has been added Amy Kim 2012 06 26 1 5 Change description of network interface Remove description about PPPoE and DHCP Extend the warranty period to two years Amy Kim 2013 02 07 1 6 Change voltage conditions of output port Amy Kim 2013 05 16 1 7 Add related material Add Exemption From Liability Add Features Amy Kim 2013 08 21 1 8 Add function of Pulse Control throug...

Reviews: