All-in-one solar charge inverter 37
Maximum
Efficiency
>92%
Overload
protection
For S model:
(102% < load <125%) ±10%: report error and turn off the output after 5 minutes;
(125% < load < 150%) ± 10%: report error and turn off the output after 10 seconds;
Load >150% ±10%: report error and turn off the output after 5 seconds;
For U model:
(102% < load <110%) ±10%: report error and turn off the output after 5 minutes;
(110% < load < 125%) ± 10%: report error and turn off the output after 10 seconds;
Load >125% ±10%: report error and turn off the output after 5 seconds;
Peak power
4000VA
6000VA
3000VA
4500VA
Loaded motor
capability
1HP
2HP
1HP
2HP
Rated battery
input voltage
24V (Minimum starting voltage 22V)
Battery
voltage range
Undervoltage alarm/shutdown voltage/overvoltage alarm /overvoltage recovery... settable on LCD
screen)
Power saving
mode
Load ≤50W
AC charging
Battery type
Lead acid or lithium battery
Maximum
charge
current(can be
set)
0-60A
0-80A
0-40A
Charge
current error
± 5Adc
Charge
voltage range
20 –33Vdc
Short circuit
protection
Circuit breaker and blown fuse
Circuit
breaker
specifications
30A
40A
Overcharge
protection
Alarm and turn off charging after 1 minute
PV charging
Maximum PV
open circuit
voltage
75Vdc
100Vdc
75Vdc
100Vdc
100Vdc
100Vdc
PV operating
voltage range
30-75Vdc
30-100Vdc
30-75Vdc
30-100Vdc
30-100Vdc
30-100Vdc
MPPT voltage
30-60Vdc
30-95Vdc
30-60Vdc
30-95Vdc
30-95Vdc
30-95Vdc