Important Notes:
Overhead Clearances
In no case shall the clearances
between the highest part of the
cooker be less than 650mm or for an
overhead exhaust fan 750 mm. All
other downward facing combustible
surfaces less than 650 mm above the
cooker surface shall be protected for
the full width of the cooking surface
in accordance with the standards
noted above. In no case shall the
clearance be less than 450 mm.
Rear and Side Clearances
• Where the dimensions from the
periphery of the nearest burner to
any vertical combustible surface
is less than 200 mm the surface
shall be protected in accordance
with the standards to a height of
not less than 150 mm above the
cooking surface for the full width
or depth of the cooking surface.
• Where the dimensions from the
periphery of the nearest burner
to any horizontal combustible
surface is less than 200 mm, the
horizontal surface shall be greater
than 10 mm below the surface of
the hob, or the horizontal surface
requirement above.
• Do not install the range near
flammable materials such as
curtains.
Installing the range on a plinth
• The freestanding oven can be
installed on a plinth without the
adjustable feet fitted.
• Ensure the freestanding oven
is secure and provide safety
measures to keep it in place.
• Cabinetry dimensions can be
adjusted to suit the plinth height,
see product dimensions for
chassis height.
FREESTANDING OVEN CLEARANCES
Product Dimensions
MM
A)
Minimum vertical distance between benchtop and
cabinet extending above the counter
450
B)
Minimum clearance from left and right hand edge
of the freestanding oven to the nearest combustible
surface*
200
C)
Minimum clearance from the top of the burner cap
(cooking surface) to:
• Overhead cabinet centered above the cooktop
(combustible/unprotected)*
• Overhead cabinet centered above the cooktop
(non-combustible/protected)*
• Ventilation hood centered above the cooking surface
650
450
750
D)
Width of cabinetry opening
900
E)
Maximum height of cabinetry immediately adjacent to
the freestanding oven (from floor to countertop)**
946
F)
Maximum depth from wall to cabinetry face
600
*
Installation clearances and protection of combustible surfaces shall
comply with the current local regulations e.g. AS/NZS5601.1 (latest
edition) Gas Installations code. The standards above specify that where
required protection shall ensure that the surface temperature of the
combustible surface does not exceed 65°C above room temperature.
**
Depending on the height of the feet adjustment. The cooking surface
must sit flush or above countertop level.
Installation Instructions (Continued)