background image

 

SOLUXTEC GmbH

 

 

Page 3 of 10 

 

1. Introduction 

This  User  Manual  refers  to  the  installation,  wiring,  handling,  maintenance  and  general 
administration of our PV-modules. Please read this Manual accurately and completely before 
configuration  and  installation  of  the  PV-plant.  All  advices  given  in  this  document  are  to  be 
handled  by  a  qualified  person,  who  has  due  to  his  professional  qualification  the  necessary 
technical  know-how.  Attention  should  also  be  paid  to  the  live  threatening  risk,  which  may 
occur  because  of  the  tension  in  conjunction  with  a  grid-feeding  PV-plant.  In  case  of  an 
improper installation of the module there is a danger of fire risk.

 

This  User  Manual  refers  to  the  on-roof  mounting,  on  flat-roof  bracing  and  on  shore 
installations with or without tracker.

 

In case of divergence towards this user manual 

SOLUXTEC GmbH 

does not incur liability for 

personal  damages  or  property  damages,  which  arise  because  of  improper  utilization, 
maintenance  or  incorrect  assembly  of  the  photovoltaic  module. 

SOLUXTEC  GmbH 

furthermore  does  not  provide  warranty  for  utilisability  and  functional  capability  of  the 
laminates in that case of divergence towards the in this user manual given advices.

 

 
 

Notice : 

 

All  details  given  in  this  document  are  corresponding  to  the  technical  condition  on  creation 
date. 

 

Subject to modifications and amendments.

 

 

 

Summary of Contents for PowerSlate Framed Mono Dark Blue Series

Page 1: ...USER MANUAL PowerSlate Framed Mono Serie Dark Blue Version 1 1 2010...

Page 2: ...LUXTEC GmbH Page 2 of 10 Index of contents 1 Introduction 3 2 Basic safety instructions 4 3 Transport and storage 5 4 Installation options 6 5 Instructions for mounting 12 6 Maintenance and cleaning 1...

Page 3: ...case of an improper installation of the module there is a danger of fire risk This User Manual refers to the on roof mounting on flat roof bracing and on shore installations with or without tracker I...

Page 4: ...f the modules must not be exceeded Never open the junction box of the photovoltaic module Only use inspected safety equipment and tools for the installation Risk of death by electric arc The solar mod...

Page 5: ...he corners and use a correspondingly soft surface Enter the modules with both hands Do not drop the modules Never use the junction box as a handle bar Pay attention on the low deflection For component...

Page 6: ...w sides of the module is allowed To assess an ideal brick course it is necessary to calibrate the generator control panel on roof before beginning of the installation In doing so the rail system shoul...

Page 7: ...e at least 10 based on the rain conditioned self purification Please avoid a partial or completely shading of the module All module connected together in series should have the same slope in order to...

Page 8: ...chnical standard IEC 60364 7 712 has to be respected Advice for fire protection The PV modules are not explosion proofed electric elements and must not be installed on explosive environment Furthermor...

Page 9: ...nds to add a security margin of 1 25 on all technical values including cable cross section inverter power etc It has to be taken into consideration that the load of the PV plant into the grid is balan...

Page 10: ...d in a way which prevents rain water penetrating into the plugs 6 Maintenance and cleaning In general it is not necessary to clean the modules if the inclination is 10 In case of persistent dirt use o...