Mechanical charges of the PV generator 

 

The modules were tested with a maximum mechanical charge of 2400 Pa (suction) and 2400 
Pa (compression) or 2400 Pa (suction) and 5400 (compression) cf page 8. Please take those 
maximal  values  into  account.  On  installation  site  all  present  snow  and  wind  loads  and  all 
national standards have to be considered and respected. In case of doubt please consult a 
mechanical stress analyst or rather an expert.

 

Grounding and substructure

 

Generally  the  laminates  are  frameless,  so  the  grounding  has  to  be  effected  at  the  metallic 
substructure. In general the installer has to ground the rails accordingly. The grounding has 
to  be  performed  with  a  self-locking  screw.  All  metallic  parts  of  the  substructure  have  to  be 
connected to the main equipotential bonding of the building. The use of a cable of 10mm² is 
recommended  for  this  task.  The  grounding  has  to  be  performed  with  a  section  of  cable  of 
16mm² to the main equipotential bonding. If a lightning protection already exists or is planned 
the PV-plant has to be integrated in this concept. In doing so all related engineer standards 
have to be respected.  

In Europe the technical standard IEC 60364-7-712 has to be respected.

 

Advice for fire protection

 

The  PV-modules  are  not  explosion-proofed  electric  elements  and  must  not  be  installed  on 
explosive  environment.  Furthermore  the  installation  cannot  be  effected  near  flames  or  on 
inflammable materials. The PV-modules must not be installed on flammable roofs. 

 

Further notice for wiring

 

The planning of  the wiring of the PV system should consider a tight  loop wiring of the plus 
and minus line. The  area enclosed by the conductors should be kept as small as possible. 
This reduces the risk of inductive coupling caused by lightning strokes.  

 

 

 

 

 

 

 

 

 

 

Summary of Contents for PowerSlate Mono Pure Glass Series

Page 1: ...SOLUXTEC GmbH Page 1 of 14 version 1 4 January 2014 User Manual PowerSlate Mono Serie PURE GLASS PowerSlate Multi Serie PURE GLASS...

Page 2: ...Page 2 of 14 version 1 4 January 2014 Index of contents 1 Introduction 3 2 Basic safety instructions 4 3 Transport and storage 5 4 Installation options 6 5 Instructions for mounting 10 6 Maintenance a...

Page 3: ...g PV plant In case of an improper installation of the module there is a danger of fire risk This User Manual refers to the on roof mounting on flat roof bracing and on shore installations with or with...

Page 4: ...sidered Also during low temperatures the maximum admissible open circuit voltage of the modules must not be exceeded Never open the junction box of the photovoltaic module Only use inspected safety eq...

Page 5: ...ng Never lay down the solar panels rough or on the corners and use a correspondingly soft surface Enter the modules with both hands Do not drop the modules Never use the junction box as a handle bar P...

Page 6: ...panel on roof before beginning of the installation In doing so the rail system should be justified absolutely equal otherwise it will come to bracing of the module and thereby it can lead to a breakag...

Page 7: ...the module Do not stand or step on the module Do not drop the module or let the object fall on the module In order to avoid broken glass of modules do not place heavy objects on the modules Do not dr...

Page 8: ......

Page 9: ...n to get the best possible earnings In addition you should pay attention on the following points The collector slope of the module should be at least 10 based on the rain conditioned self purification...

Page 10: ...the main equipotential bonding of the building The use of a cable of 10mm is recommended for this task The grounding has to be performed with a section of cable of 16mm to the main equipotential bondi...

Page 11: ...f the module During operation of the PV plant it could be that the given technical values of tension and current are in real higher than calculated before under STC In order to prevent a possible disp...

Page 12: ...following reference notes are to be adhered during the installation on location During work on roof all accident prevention regulations have to be respected It is recommended to protect all uninvolved...

Page 13: ...t use only classic glass cleaner or cleaning alcohol Do not use galling or chemical cleaners do not scrape the module All modules are maintenance free but it could be useful to verify the PV installat...

Page 14: ...A SOLUXTEC GmbH Route de Luxembourg 74 Werner von Siemens Stra e 25 L 6633 Wasserbillig D 54634 Bitburg Luxembourg Deutschland Phone 352 267410 Phone 49 0 6561 6937 265 Fax 352 26741080 Fax 49 0 6561...

Reviews: