Pay attention to all warning notices and safety indication that are attached to the 
panel.

 

 

The realized PV generator must not be perpetrated.

 

 

 

3. Transport and storage

 

During transport and interim storage the following point are to be observed:

 

 

The handling with the modules should always been handled with due care.  

 

 

Any operation of the photovoltaic panel is to be made with clean and soft protective 
gloves. 

 

 

The laminates are very shock-sensitive. Therefore during transport, charging and 
discharging, storing temporarily and mounting of the PV-elements you have to be 
extremely careful with the handling. Never lay down the solar panels rough or on the 
corners and use a correspondingly soft surface. Enter the modules with both hands. 
Do not drop the modules. 

 

 

Never use the junction box as a handle bar. 

 

 

Pay attention on the low deflection of the modules during handling. 

 

 

For component storage use a dry, ventilated room. 

 

 

Do not accumulate the photovoltaic panels. 

 

 

Do not use the photovoltaic panels as a support. 

 

 

Keep all parts clean, which may come in contact with the PV-element. 

 

 

The modules are qualified for use in the application class A: Hazardous voltage (IEC 
61730: greater than 50Vdc, EN 61370: greater than 120Vdc), hazardous power 
applications where generally unrestricted accessibility is expected (For modules in 
this application class according to EN IEC 61730-1 and -2 are qualified, it is assumed 
that they meet the requirements of protection class II)  

 

 

 

 

 

 

Summary of Contents for PowerSlate Mono Pure Glass Series

Page 1: ...SOLUXTEC GmbH Page 1 of 14 version 1 4 January 2014 User Manual PowerSlate Mono Serie PURE GLASS PowerSlate Multi Serie PURE GLASS...

Page 2: ...Page 2 of 14 version 1 4 January 2014 Index of contents 1 Introduction 3 2 Basic safety instructions 4 3 Transport and storage 5 4 Installation options 6 5 Instructions for mounting 10 6 Maintenance a...

Page 3: ...g PV plant In case of an improper installation of the module there is a danger of fire risk This User Manual refers to the on roof mounting on flat roof bracing and on shore installations with or with...

Page 4: ...sidered Also during low temperatures the maximum admissible open circuit voltage of the modules must not be exceeded Never open the junction box of the photovoltaic module Only use inspected safety eq...

Page 5: ...ng Never lay down the solar panels rough or on the corners and use a correspondingly soft surface Enter the modules with both hands Do not drop the modules Never use the junction box as a handle bar P...

Page 6: ...panel on roof before beginning of the installation In doing so the rail system should be justified absolutely equal otherwise it will come to bracing of the module and thereby it can lead to a breakag...

Page 7: ...the module Do not stand or step on the module Do not drop the module or let the object fall on the module In order to avoid broken glass of modules do not place heavy objects on the modules Do not dr...

Page 8: ......

Page 9: ...n to get the best possible earnings In addition you should pay attention on the following points The collector slope of the module should be at least 10 based on the rain conditioned self purification...

Page 10: ...the main equipotential bonding of the building The use of a cable of 10mm is recommended for this task The grounding has to be performed with a section of cable of 16mm to the main equipotential bondi...

Page 11: ...f the module During operation of the PV plant it could be that the given technical values of tension and current are in real higher than calculated before under STC In order to prevent a possible disp...

Page 12: ...following reference notes are to be adhered during the installation on location During work on roof all accident prevention regulations have to be respected It is recommended to protect all uninvolved...

Page 13: ...t use only classic glass cleaner or cleaning alcohol Do not use galling or chemical cleaners do not scrape the module All modules are maintenance free but it could be useful to verify the PV installat...

Page 14: ...A SOLUXTEC GmbH Route de Luxembourg 74 Werner von Siemens Stra e 25 L 6633 Wasserbillig D 54634 Bitburg Luxembourg Deutschland Phone 352 267410 Phone 49 0 6561 6937 265 Fax 352 26741080 Fax 49 0 6561...

Reviews: