35
Language
To select the
language
, press “set”. Using the “+” or “-” keys, select the desired
language (
Pt
– Portuguese;
Nl
– Dutch;
Gr
– Greek;
It
– Italian;
En
– English;
Fr
–
French;
Es
– Spanish;
De
– German). Press "ok" to confirm.
Press the "+" key to go to the "eco" menu.
Eco mode
If the unit is equipped with a thermostat that operates exclusively based on the
temperature, the "eco mode" can be enabled to reduce the fuel consumption. In this
mode, the unit operates at a set point temperature. The unit always runs at maximum
operating power until it reaches a temperature of 33.8ºF (1ºC) above the set point
temperature. Upon reaching this temperature, the unit starts operating at minimum
operating power for a preset time period. After this time has elapsed, the unit turns off. It
remains off for another preset period of time. When the measured room temperature
drops to a preset value, the unit turns on again at the maximum operating power.
This operation is only available in automatic mode.
To activate the eco mode, press "set". The display starts to flash. Select "On" or "Off"
using the "-" and "+" keys. Press "set" to confirm the selection.
Press "esc" to return to the previous menu and "+" to go to the "Iluminação" (Lighting)
menu.
Summary of Contents for Alpes 10 kW
Page 22: ...19 b c Figure 17 Examples of standard installations ...
Page 52: ...49 b c d e f g Figure 33 Installation of the UPS kit ...
Page 61: ...58 a b c d e f ...
Page 70: ...67 13 5 Symbols Figure 60 Symbols ...
Page 71: ...68 14 Electrical diagram of the Free Standing Pellet Fire unit Figure 61 Electrical diagram ...
Page 78: ...75 ...