61
12. Alarms / failures / recommendation list
Table 2
– List of alarms
Important note: all alarms cause the machine to shut down. The alarm must be
reset and restarted.
To reset the unit press the “On/Off” button for 10 seconds until the
alarm sounds.
Alarm
Code
Troubleshooting
Ignition failure
A01
Maximum time 2400
sec
- the worm drive channel is empty - restart the
unit
- resistance burnt
– replace resistance
- the burning basket has been incorrectly
installed
No flame or lack of pellets
A02
Temperature under:
- 104ºF (40°C) (air
model)
- 109.4ºF (43°C)
(backboiler model)
- Pellet reservoir is empty
Excess heat in the pellet
drum
A03
194ºF (90°C)
- the fan is not working
– call for assistance
- faulty thermostat - call for assistance
- machine with faulty ventilation
Excess fume temperature
A04
Over 446ºF (230°C)
(air model);
Over 446ºF (260°C)
(backboiler model)
- the fan is not working or is working at a low
power level - increase the level to the
maximum (if the problem persists, call for
assistance)
- Insufficient extraction
- Excess pellets
Pressure switch alarm
A05
The door is open, lack
of draught or extractor
fault for 60 sec
- close the door and clear the error message
on the faulty pressure regulator
- obstruction of the exhaust pipe or faulty
extractor
Air mass probe
A06
40 Ipm delta for 3600
sec
- pipes with insufficient extraction or obstructed
pipes
The door is open
A07
Door open for 60
seconds
- close the door - clear the error message
Fume extractor is faulty
A08
Connection failure
- check connection
Fume probe failure
A09
Connection failure
- check connection
Pellet resistance error
A10
Connection failure
- check connection
Worm drive error
A11
Connection failure
- check connection
Pellet level alarm
A15
- check connection
Water pressure outside
operating range
A16
- check connection
Excess water temperature
A18
- check connection
Summary of Contents for Alpes 10 kW
Page 22: ...19 b c Figure 17 Examples of standard installations ...
Page 52: ...49 b c d e f g Figure 33 Installation of the UPS kit ...
Page 61: ...58 a b c d e f ...
Page 70: ...67 13 5 Symbols Figure 60 Symbols ...
Page 71: ...68 14 Electrical diagram of the Free Standing Pellet Fire unit Figure 61 Electrical diagram ...
Page 78: ...75 ...