Solzaima offers you an optional safety system which allows the Free Standing Fire
unit to be connected to a UPS so that during any power failure the fume extractor will still
operate until complete extraction of all the fumes;
If you intend to use the Free Standing Fire unit while you are away from home or
unattended, you should use the safety system specified above for total safety during any
power failure;
During operation, NEVER turn off the free standing fire unit by disconnecting the
electric plug. The fume extractor on the free standing pellet fire unit is electric so
disconnecting the power plug will prevent the extraction of combustion fumes;
Your unit must be disconnected from the mains for servicing. Before doing this, the
unit must be totally cooled down (if operating before);
Never touch the interior of the unit without disconnecting it from the power mains;
On backboiler models, the maximum temperature of the water that can be set by the
user (water set-point temperature) is 85°C. In the event of a temperature of 90ºC being
reached, the free standing pellet fire unit automatically disconnects and the respective
alarm is activated.