29
Failure to comply with these requirements may prevent the correct operation of
the unit, resulting in warranty void. Be sure to follow all the instructions on the
diagrams.
The insert operates with the combustion chamber in draught, which is why it is
absolutely necessary that they include a fume exhaust duct to adequately extract
combustion gases.
Fume duct material:
The tubing must consist of 0,5 mm thick rigid stainless steel,
with fitting bindings to attach the different sections and accessories.
Insulation
: The fume ducts must be double-walled and insulated to make sure the
fumes do not cool down going outwards, which could cause an inadequate
circulation and condensation that may damage the unit.
Output “T-tube”:
Always attach to the output of the unit a "T-tube" with a
damper.
Chimney Crown:
A wind shield termination must be installed to avoid fume back
flow.
Chimney draught
: The Figures below show three standard diagrams, specifying
adequate lengths and diameters. Any other type of installation must guarantee a
draught of 12 Pa (0,12 mbars) measured when hot and at the maximum power.
Ventilation:
To get the optimum operation from the unit
it is necessary that the
installation location has an air inlet with a minimum section of 100 cm
2
,
preferably near the back panel of the unit
.
If the house is equipped with an air exhaust system (e.g. kitchen extractor
fan), a top ventilation section must be installed, suitable to accommodate
the different air exhaust systems existing in the household. The
installation of the unit on locations near kitchen exhaust fans or fume
extractors may prevent the unit from operating properly. It is
recommended that the unit is disconnected when these extractors are
working.
Summary of Contents for Atlantic
Page 77: ...76 ...
Page 78: ...77 ...
Page 79: ...78 ...
Page 85: ...84 20 Electrical Diagram of the Fire Unit Figure 68 Electrical diagram ...
Page 100: ...99 25 2 Flow chart Flow chart 1 Lighting ...
Page 101: ...100 ...
Page 102: ...101 Flow chart 2 Disabling Note The circulator pump off below 40 C water temperature ...