82
Connection to central heating radiators with another boiler support and
sanitary water combined with solar panel
Figure 65 – Connection to central heating radiators with another boiler support and sanitary water combined with
solar panel
Notes:
- The chrono-thermostat should have 15 to 25 °C of hysteresis.
- Hydro independent "Off" (water temperature-controlled regulation), put
the boiler in "manual" mode and power level to "5"
- Modulating pump "On"
- Water sensing inhibition "On"
- Alternative hydro shutdown "On"
- Pump "On" = 50 °C
- Pump "Off" = same or thermostat temperature 1°C below the temperature
differential thermostat
When using the generator with differential thermostat the machine must be
connected in the CONNECTION "Remote".