4
combustion, so possible air tightness of the location or any existing air extraction
sources in the room may prevent the unit proper operation;
• The existence of vents is a requisite for proper combustion;
• Do not leave the packing materials near children;
• During normal operation, Free Standing Fire unit's door must not be opened;
• Some parts of the unit may overheat during normal operation, so avoid direct
contact with parts such as the door handle and glass;
• Check the existence of any obstructions on the fume duct before turning on the unit
after a long period of inactivity;
• This free standing pellet fire unit is intended for residential use in protected areas.
Safety systems may turn off the unit. If this occurs, contact the technical assistance. In
any circumstances should you attempt to interfere with the safety systems;
• The free standing pellet fire is a biomass heating unit equipped with an electric
fume extractor. The occurrence of any power failure during its use may prevent fume
extraction and the room will be filled with smoke. For this reason, you should have a
natural fume extraction system, like a chimney, available;
• Solzaima offers you an optional safety system which allows the Free Standing Fire
unit to be connected to a UPS so that during any power failure the fume extractor will
still operate until complete extraction of all the fumes;
• If you intend to use the Free Standing Fire unit while you are away from home or
unattended, you should use the safety system specified above for total safety during
any power failure;
• During operation, NEVER turn off the free standing fire unit by disconnecting the
electric plug. The fume extractor on the free standing pellet fire unit is electric so
disconnecting the power plug will prevent the extraction of combustion fumes;
• Your unit must be disconnected from the mains for servicing. Before doing this, the
unit must be totally cooled down (if operating before);
• Never touch the interior of the unit without disconnecting it from the power mains;
• On backboiler models, the maximum temperature of the water that can be set by
the user (water set-point temperature) is 85°C. In the event of a temperature of 90ºC
being reached, the free standing pellet fire unit automatically disconnects and the
respective alarm is activated.
Summary of Contents for Douro 12
Page 5: ......
Page 60: ...55 a b c d e f ...
Page 66: ...61 ...
Page 67: ...62 ...
Page 68: ...63 ...
Page 89: ...84 23 2 Flow chart Douro 12 kW Flow chart 1 Lighting ...
Page 90: ...85 ...
Page 91: ...86 Flow chart 2 Disabling Note The circulator pump off below 40 C water temperature ...
Page 92: ...87 23 3 Flow chart Douro 17 kW and Douro 23 kW Flow chart 1 Lighting ...
Page 93: ...88 ...
Page 94: ...89 Flow chart 2 Disabling Note The circulator pump off below 40 C water temperature ...