Installing the Free Standing Pellet Fire
Before installing the unit, please follow these steps:
Upon delivery, please check the product for completeness and to determine the
existence of any signs of damage. Any damages or defects should be accounted for
before the unit is installed.
This unit is equipped with four feet at the base, adjustable in height, allowing for
the easy regulation when installing the unit on a non-leveled surface.
a) b)
Figure 4 – Adjustable feet
Remove the instruction manual from the package and hand it over to the client;
Connect an 80 mm-wide duct between the combustion gas output and the outgoing
fume extraction duct of the building (e.g. chimney). See location diagrams, sections
5.1 to 4.3.
The tube used for combustion air inlet from the outside, if installed, must be
straight (no bends) and have a maximum length of 60cm horizontally;
Connect the 230VAC power cable to a grounded socket.
The hot air outlet side of the unit must be installed facing the area to be heated.
5.1. Installation Requirements
The minimum distance between the free standing pellet fire unit and particularly
flammable surfaces is specified in figure 5.
The top of the unit must have a separation distance from the ceiling of at least 100cm,
especially in rooms with ceilings made of flammable materials.
The base used to support the unit cannot be made of combustible materials (e.g.
carpet), so make sure adequate protection is used.