11
The pipes external to the operating area must have double stainless steel insulation
and an internal diameter of 80mm.
The fume exhaust pipe may generate condensation, so the installation of
appropriate systems for collecting condensates is recommended.
“All national and local regulations and European Standards shall be complied with
when operating the appliance”
5.3. Installing Without a Chimney
The installation of the Free Standing Pellet Fire when no chimney is present must be
performed as illustrated in Figure 6,
by directing an exhaustion pipe (with a minimum
diameter of 80mm) through the ceiling opening to the outside and over the roof.
Properly attached double-walled stainless steel insulated pipes must be used to avoid
condensation.
A T-tube must be installed at the base of the pipe to allow periodic inspections and
annual maintenance, as illustrated in Figure 6.
figure 7 illustrates the basic requirements for installing the flue onto the unit
Figure 6 – Side view of the installation without a chimney, showing the inspection point.