15
Figure 8 – Side view of the installation without a chimney, showing the inspection point.
The Free Standing Pellet Fire should not be operated in adverse weather conditions,
because these may seriously impact the draught (particularly with very strong winds).
If the unit has not been used for a long period of time, before lightening the fire, check
the unit to make sure that the flue pipes are clean and unblocked.
6.
Hydraulic Installation
* Chapter 16 (installation diagrams) includes diagrams illustrating the range of possible
connections that may be used in the installation of a central heating system, with or
without the feature of heating water for domestic use;
* The pellet-run boiler comes equipped with a circulating pump, an expansion tank with
a volume of 6 litres pre-charge pressure of 1.0 bar, as well as a 3 bar safety valve;
* Operating pressure is between 1 and 1.5 bars;