30
9.2.7.
Settings Menu
To modify the unit's settings, press "Set". The "Língua" ("Language") menu should
then appear, allowing the user to choose a set language.
ON
OFF
OF
F
+
OK
OFF
MENU
OFF
MODE
OFF
ESC
OFF
-
MAN
AUT
OFF
esc
Set
<
Configurações
>
Language
To select the language, press “set”. Using the “+” or “-” keys, select the language (Pt
– Portuguese; Nl – Dutch; Gr – Greek; Tr – Turkish; It – Italian; En – English; Fr –
French; Es – Spanish; De – German). Press "ok" to confirm. Press the "+" key scroll
go to the "Eco" menu.
Eco mode
When the “ECO” mode is enabled at the same time as the Thermostat feature, the unit
will operate at maximum power until the thermostat opens contact (NO). The unit then
will operate at minimum power for a preset period of time (Shutdown delay time:
factory setting: 20 minutes). Once the preset time is elapsed, the unit shuts down. At
the start of the Shutdown phase, another timer for a different preset period of time is
triggered (Start-up delay time: factory setting: 20 minutes), that will make the unit
enter the activation phase, when the thermostat closes contact (NC)
Start-up delay time (Delay time On): The delay time that elapses between the
moment the thermostat closes (NC) until the unit is activated.
Shutdown delay time (Delay time Off): The delay time that elapses between the
moment the thermostat opens (OC) until the unit starts to shutdown.
Note: When using the feature for the first time, you must press the On/Off button in
the display. To enable the eco mode, press “set”. The display starts to flash. To activate
the eco mode, press "set". The display starts to flash. Select "On" or "Off" using the "-"
Summary of Contents for Douro 12kW
Page 13: ...12 a b ...
Page 50: ...49 ...
Page 51: ...50 ...
Page 52: ...51 ...
Page 58: ...57 18 Electrical Diagram of the Free Standing Fire Unit Figure 40 Electrical diagram ...
Page 70: ...69 21 Annexes 21 1 Flow chart Lighting ...
Page 71: ...70 ...
Page 72: ...71 Disabling ...