32
not to cause unwanted oxidation. The sealing cord is glued and should
therefore not be wetted with water or cleaning products.
a) Incorrect b) Liquid application on the cloth c) Cleaning with a cloth
Figure 20 – Glass cleaning
12.2.
Daily/weekly maintenance
For daily cleaning, the door must be opened by removing the burner and cleaning the
ashes inside the combustion chamber. Also, clean the ashes inside the burner to ensure
that the burner holes are completely unobstructed (see Figure 21-c). Put the burner
back in place and close the door.
a) Burner removal b) Interior cleaning c) Burner cleaning
Figure 21 – Limpeza do interior da camara de combustão e o queimador
WARNING! the frequency of maintenance tasks depends on the quality of
the pellets..
Note: See label with warnings and maintenance tasks in chapter 15.
.
12.2.1.
Additional cleaning
For each 600-800 Kg of pellets consumed, an additional cleaning must be made..
12.2.2.
Cleaning the fume passage K50
To perform this cleaning, you must remove the worktop (pull the worktop upwards,
spring fit), the side covers and the lower front grille inside the door. To remove these
parts it is necessary to remove some screws. Once the covers have been removed,
remove the side and front covers of the combustion chamber, then, using a vacuum