Technical characteristics*
Characteristics
K50
Units
Height
823
mm
Width
450
mm
Depth
549
mm
Diameter of the fume discharge pipe
80
mm
Tank capacity
11
kg
Maximum heating volume
137,5
m³
Maximum overall thermal input
6,1
kW
Minimum thermal input
3,2
kW
Minimum fuel consumption
0,7
kg / h
Maximum fuel consumption
1,36
kg / h
Rated electrical power
89
W
Electrical power at start (<10 min.)
362
W
Rated voltage
230
V
Nominal frequency
50
Hz
Thermal efficiency at rated thermal input
92
%
Thermal efficiency at reduced thermal input
95
%
Maximum gas temperature
123
°C
Temperature min. of gases
66
ºC
CO emissions at nominal thermal power
0,01
%
CO emissions at reduced thermal power
0,04
%
Mass flow of combustion gases
5
g/s
Depression in the chaminé
12
Pa
Table 1 – Technical characteristics
*Tests performed using wood pellets with a calorific value of 4.9 kWh/kg.
The above data were obtained in the product homologation tests in independent and accredited
laboratories, in order to carry out tests on pellet equipment.