31
8.
Use of the pellet-run boiler
Before starting up the unit, please check the following:
Guarantee that the boiler is properly connected to the power mains by means of
the 230 VAC power cable.
Figure 26 - Electric power plug
Check that the pellet reservoir is full.
Before each start, make sure that the burner is unobstructed.
Ensure that the hydraulic circuit has been correctly assembled and is connected to
the water.
Check that there is sufficient air circulation in the room where the installation is to
be carried out, otherwise the equipment will not work properly. For this reason, pay
attention to whether there are other heating appliances that consume air for their
operation (e.g., gas appliances, diesel boilers, etc.), and it is not advisable to operate
these appliances at the same time.
The boiler has a manual reset safety thermostat to prevent excessive
temperatures in the boiler body. To reset this thermostat, open the right door and
remove the black plastic cover covering the thermostat reset. Press all the way down.
To be reset, it must be below 95°C.
Figure 27 - Temperature safety thermostat