13
6.
Installation Requirements
The minimum distances from the wood boiler to flammable surfaces are shown in
Figure 11.
At the top of wood boiler, it is necessary to maintain a minimum distance of 100 cm
from the ceiling of the room especially if they contain flammable material in their
composition.
The base on which the boiler is supported must not be of combustible material, so
adequate protection must always be provided.
a)
b)
Figure 11 – Minimum distances to all surfaces: a) top view of the installation of equipment; b) side view of
the installation device
In Figure 12 and Figure 13, the basic requirements for the installation of the boiler
flue are shown. Provide a T for the periodic inspections and the annual maintenance,
as exemplified in the figures. Double-walled insulated stainless-steel pipes should be
used properly to avoid condensation.