Somat eDAQ
lite
6 Input Channels
This chapter details all of the available input channels and their parameters. To acquire
data during a test, define input channels for each input signal in the transducer setup
window. Input channels can be transducer channels, message channels or data
channels derived from various message-oriented data sources. Each channel
definition contains some common information such as the ID tag, the hardware
connector ID, output data type, desired full-scale range and output sample rate. In
addition, each channel type has specific parameters that must be defined.
6.1
Common Input Channel Parameters
6.1.1
Desired Measurement
ID
Specify a unique identifier for the channel. The name must conform to ID naming
conventions. Valid ID names:
•
are case sensitive
•
are limited to a maximum of 12 characters
•
contain only valid characters (i.e., letters (a-z, A-Z), digits (0-9), and the
underscore (_) character)
•
start with a letter
•
are not duplicates of system reserved names (sin, cos, log, etc.)
Connector
Hardware connector IDs identify connector assignments for transducers. The default
ID consists of the eDAQ
lite
IP address or host name, layer identifier and the
physical/logical channel as specified in the hardware setup. The following examples
illustrate the eDAQ
lite
conventions.
•
ELBRG: For an ELBRG layer with an ID of Brg_1, connector IDs Brg_1.c01
through Brg_1.c16 denote the set of 16 bridge transducer connections.
•
ELDIO: For an ELDIO layer with an ID of DIO_1, connector IDs DIO_1.apc1
through DIO_1.apc6 denote the set of 6 pulse counter connections on Bank A.
Description
Use up to 63 characters to more fully identify the transducer.
Type
Specify the type of measurement, such as strain, load or acceleration, associated with
the transducer or computed channel. Select a type from the list or directly enter a
user-defined type. Since TCE uses the value of the type field throughout the test setup
process, always complete this field.
Units
Specify the measurement units for the transducer. Since TCE uses the value of the
units field throughout the test setup process, always complete this field.
HBM: public
Summary of Contents for eDAQlite
Page 1: ...User Manual English Deutsch Espanol I2773 4 4 en HBM public Somat eDAQlite with TCE Software ...
Page 2: ...Somat eDAQlite 2 I2773 4 4 en HBM public ...
Page 16: ...Somat eDAQlite 16 I2773 4 4 en HBM public ...
Page 22: ...Somat eDAQlite 22 I2773 4 4 en HBM public ...
Page 88: ...Somat eDAQlite 88 I2773 4 4 en HBM public ...
Page 106: ...Somat eDAQlite 106 I2773 4 4 en HBM public ...
Page 128: ...Somat eDAQlite 128 I2773 4 4 en HBM public ...
Page 190: ...Somat eDAQlite 190 I2773 4 4 en HBM public ...
Page 202: ...Somat eDAQlite 202 I2773 4 4 en HBM public ...
Page 222: ...Somat eDAQlite 222 I2773 4 4 en HBM public ...
Page 224: ...Somat eDAQlite 224 I2773 4 4 en HBM public ...