7.2.9
Damage Equivalent Load
The Damage Equivalent Load channel generates an accumulated equivalent load
range value as a function of the user-defined damage slope parameter and the
associated accumulated rainflow cycle count for the selected input channel.
NOTE
The Damage Equivalent Load channel has two outputs, load and cycle, each of which
has its own name, description, type, units, full-scale min and max, and data type fields.
The eDAQ
lite
processes the input channel through a rainflow cycle counter using the
user-defined hysteresis value for peak picking. For each closed cycle, the eDAQ
lite
computes a load damage parameter as (closed cycle range ^ damage slope) and
adds it to the running sum that accumulates load damage on a cycle-by-cycle basis.
For each output sample, the eDAQ
lite
processes the residual peak-valley sequence
through the rainflow cycle counter to account for the additional accumulated load
damage and accumulated closed cycle counts. The Damage Equivalent Load output
value (
S
eq
) is computed using the following equation:
where,
x
i
is the load damage for each closed cycle,
N
is the number of closed cycles
and
m
is the damage slope.
For more information on the data processing algorithms used, see
Input Channel
The input channel data type must be 32-bit float.
Output Data Type
Both output channel data types are 32-bit float.
Hysteresis
Set the desired hysteresis level for the peak valley processing algorithm.
Damage Slope
Set the damage slope used in the processing algorithm as described above. This can
be any value from 1.0 to 20.0.
Window Samples
Specify the number of input samples used to generate one output sample. This sets
the analysis window size and associated output sample rate. Specify any positive
integer value greater than one.
NOTE
There can be fairly significant computational overhead in generating each output
sample, particularly when the residual peak-valley sequence is relatively long (i.e., 100
residual peak-valleys or more). Consider the computational overhead when specifying
the window samples.
HBM: public
Summary of Contents for eDAQlite
Page 1: ...User Manual English Deutsch Espanol I2773 4 4 en HBM public Somat eDAQlite with TCE Software ...
Page 2: ...Somat eDAQlite 2 I2773 4 4 en HBM public ...
Page 16: ...Somat eDAQlite 16 I2773 4 4 en HBM public ...
Page 22: ...Somat eDAQlite 22 I2773 4 4 en HBM public ...
Page 88: ...Somat eDAQlite 88 I2773 4 4 en HBM public ...
Page 106: ...Somat eDAQlite 106 I2773 4 4 en HBM public ...
Page 128: ...Somat eDAQlite 128 I2773 4 4 en HBM public ...
Page 190: ...Somat eDAQlite 190 I2773 4 4 en HBM public ...
Page 202: ...Somat eDAQlite 202 I2773 4 4 en HBM public ...
Page 222: ...Somat eDAQlite 222 I2773 4 4 en HBM public ...
Page 224: ...Somat eDAQlite 224 I2773 4 4 en HBM public ...