CLEANING THE HYDRA-EXTRACTOR
:
1.
With high pressure hose, wash down screens and interior walls of Hydra-
Extractor
housing. If necessary, a long-handled brush can be used.
B.
Long Term Shut Down Procedure -
If the Pulper is to remain idle
for a relatively long period (four weeks or more), special procedures
should be taken to protect the equipment. These procedures are as
follows:
1.
Perform the daily cleaning procedure, and then circulate a solution
of a cleaning and disinfecting agent through the lines to combat
bacteria growth and odor.
2.
Remove the impeller from the Pulper, (refer to Pulper Maintenance
Section). Do not remove the mechanical seal. Using a hose and
brush, thoroughly clean the mechanical seal, slurry chamber, and
the underside of the impeller.
***To ensure all food waste is removed from the extractor, you can use Styrofoam plates
as a cleaning agent for the unit. The Styrofoam will force out the majority of food waste
leaving only Styrofoam. Run the plates as you would any waste, and continue until
nothing but Styrofoam exits the extractor. We do not recommend using cardboard as it
will dry out and create a very hard obstruction in the extractor which could cause motor
overload on restart.***