Calculateur EL-250
SOMECO –
someco@someco.fr
– Tel : 01 49 63 16 30 -
Manuel d’utilisation
P a g e
|
16
6.1.2. Apply
compensation
Go to
Setup
X or Y axis Settings
5. Apply compensation
to select
compensation type amongst None, LComp and SComp.
Note:
The user will have to perform machine reference on every power ON if SComp
is selected for an axis.
It is necessary to refer to the same reference mark /
machine reference
which was used while performing SLEC compensation.
6.1.3.
Calibration procedure for
θ
(Angular) Axis
User can enter CPR(Counts/Rotation) value directly and calibrate the
θ
-
axis. For this
go to
Setup
θ
-Axis Settings
Counts/Rotation.
The first option of this menu
shows the current CPR set in the machine. To edit CPR directly press
and edit the value.
Counts Per Rotation (CPR) = Pulses Per Rotation (PPR) X 4
MANUAL CPR CALIBRATION
(non traduit concerne uniquement le service
technique)
If the user does not know the CPR of angular axis then he can manually calculate
the CPR by the following manual calibration procedure. For manual calibration go to
Setup
θ
-Axis Settings
Counts/Rotation
Calibration.