30
EN
- GDK 700 installation and operating guide - SOMFY
EN
5
Maintenance and repairs
5.2 Diagnostics
5.3 Assistance
Indicator light B
Meaning
Solution?
2
Motor waiting for
auto-programming.
Start auto-programming
3
Cell fault.
•
Check that no obstacles prevent the cells
from detecting.
•
Check the wiring of the cells or create a
bridge between terminals 1 and 2 if no
cells are installed.
•
Check the correct alignment of the cells.
5
Motor thermal protection device
Leave the motor to cool until the
fault disappears.
6
Motor current measuring circuit
fault or sensor fault.
•
Switch off the power supply (mains and
backup battery), wait a few minutes then
reconnect the power supply.
•
Perform an auto-programming cycle.
If the fault persists, contact Somfy
technical support.
7
Maximum power delivered by
the motor reached during
the auto-programming phase.
Product has reached operating limit.
If the fault remains or for any other problem or enquiry relating to your motorisation, visit:
www.somfy.com
5.1 Periodic checks
Refer to the
Safety instructions
booklet, chapter 9 - “Safety instructions relating to maintenance”.
WARNING