7.3. Lighting time delay - Dipswitch 5
DIP - SW 5
Setting
OFF
30 seconds
ON
120 seconds
7.4. Wire input operating modes - Dipswitch 6
DIP - SW 6
Setting
OFF
Control always open / always closed
ON
Sequential control / always closed
7.5. Operating modes - Dipswitches 7 to 9
DIP -
SW 7
DIP -
SW 8
DIP -
SW 9 Setting
Sequential
OFF
OFF
OFF
Each press on the remote control causes
the motor to move (initial position: barrier
closed) as per the following cycle: open,
stop, close, stop, open, etc.
Sequ automatic timed close
OFF
OFF
ON
Operation in automatic closing mode is only au-
thorised if the photoelectric cells with autotest
are fitted.
In sequential mode with automatic timed close:
• the barrier closes automatically after the time
delay programmed with the TIME potentiom-
eter,
• pressing a button on the remote control
interrupts the movement taking place and the
closure time delay (the barrier remains open).
Semi-automatic
OFF
ON
OFF
• pressing the button on the remote control
while the gate is opening will stop the barrier,
• pressing a button on the remote control dur-
ing closing causes the barrier to reopen.
Automatic
OFF
ON
ON
In automatic mode, the final position of the
barrier will always be the closed position.
Operation in automatic closing mode is only au-
thorised if the photoelectric cells with autotest
are fitted.
• the barrier closes automatically after the time
delay programmed with the TIME potentiom-
eter,
• pressing a button on the remote control
during opening has no effect,
• pressing a button on the remote control dur-
ing closing causes the barrier to reopen,
• pressing a button on the remote control
during the closing time delay restarts the time
delay (the barrier will close when the new
time delay has elapsed).
If there is an obstacle in the cells’ detection
zone, the barrier will not close. It will close once
the obstacle is removed.
DIP -
SW 7
DIP -
SW 8
DIP -
SW 9 Setting
Aut cell blocking
ON
OFF
OFF
In automatic mode, the final position of the
barrier will always be the closed position.
Operation in automatic closing mode is only au-
thorised if the photoelectric cells with autotest
are fitted.
After the barrier is opened, movement in front
of the cells (if active cell input during closing is
activated) will close the gate after a short time
delay (fixed at 2 seconds).
If there is no movement in front of the cells,
the barrier will close automatically after the
closing time delay programmed with the TIME
potentiometer.
If there is an obstacle in the cells’ detection
zone, the barrier will not close. It will close once
the obstacle is removed.
Deadman's wired control
ON
ON
ON
The barrier can only be controlled by continuous
action on a wired control: opening to the OPEN
control input (regardless of how dipswitch 6 is
configured), closing to the CLOSE control input.
The radio controls are inactive.
There is no slowdown zone when the deadman’s
wired control is operating,.
7.6. Safety edge autotest - Dipswitch 10
DIP - SW 10
Setting
OFF
Without autotest
ON
With autotest
7.7. Orange light warning - Dipswitch 11
DIP - SW 11
Setting
OFF
Without warning
ON
With 2 s warning prior to movement
7.8. Cell autotest when closing - Dipswitch 12
DIP - SW 12
Setting
OFF
Without autotest
ON
With autotest: the autotest is only available
for the cell connected to the cell active during
closing input.
7.9. Setting the closing time delay - Fig. 30
Set the timed close (up to 120 s delay) with the TIME potentiometer if the
"Sequ automatic timed close", "Automatic" or "Aut cell
blocking" operating mode is selected:
• Turn the potentiometer to the right to increase the time delay.
• Turn the potentiometer to the left to decrease the time delay.