Danger!

Danger of hands being crushed. While
the ledge is moving, never put your
hands between the fixed frame and
moving parts.

•   If the motor does not cut out when the end of

stroke is reached, proceed as follows:
1) Disconnect the actuator from the power 
supply.
2) Immediately contact the SOMFY
Technical-Sales Department.

These wiring instructions are directed
exclusively at specialised persons who are
qualified to install electrical systems. Such
persons must at all times comply with 
current regulations governing electrical
installations.

Danger!

In order to eliminate the danger of
electric shock, disconnect the controls
from the power supply before working
on the actuators or the electrical
system. Always fit a bipolar main power
switch upstream of the control line cable
with a gap of at least 3 mm between
contacts.

Warning!

If safety devices prevent the window
from being fully opened, or if the
window is opened less than the full
stroke of the actuator, the actuator or
the window may be damaged.

D

CONNECTING TO THE 

POWER SUPPLY

INSTRUCTIONS ON FITTING, USING AND
MAINTAINING THE ACTUATOR

Linkeo 2

7

Danger!

If the actuator to be installed is in the
24V DC version, it must be 
connected to the mains with a 
double insulation power supply with
very low safety voltage that is 
properly sized for its use. Also the 
following power supply and system 
characteristics must be observed:
Supply voltage:                 

24V+/- 6%

Ripple max:

+ / - 1 0 %

Max supply line capacity:                250 nF
Max supply line inductance:             10 mH

Warning!

Always arrange for the installation of
changeover switches with mid OFF
position with “man present” control or
equivalent. The position of the three-
way switch buttons must be outside the
field of action of the
moving part of the window.
Connection to the mains is carried out
by means of cables with wires of 1 mm2
minimum section having the appropriate
length to reach the junction box, which
must be placed near the actuator. The
electric conducts must be properly sized
according to the needs of each single
system.
It is recommended that remote controls,
if any, are installed in a position that lets
you see the controlled automation and

at a minimum height of 1.5 m.
If the actuator is expected to operate
unattended (automatic or remote 
operation), it is advisable to install 
additional safety devices.
To power any signalling source, it is 
prohibited to use a voltage different than
that indicated on the rating plate of the
actuator.

Warning!

For a working voltage lower than 42V,
the actuator is declared Class III
Device. The intended use of the
actuator is at extra low safety voltage.
The term extra low safety voltage
means a voltage rating no higher than
40V between the cables and between
the cables and the ground. No load
voltage shall exceed 50V. If the extra
low safety voltage is obtained through
the mains, we recommend use of a
safety transformer or a converter with
separated windings the insulation of
which must comply with the rules
regarding double insulation or
reinforced insulation. The term safety
transformer means a transformer the
primary winding of which is electrically
separated from the secondary windings
by an insulation at least equivalent to
the double insulation or to the
reinforced insulation.

Summary of Contents for Linkeo 2

Page 1: ...States SOMFY SYSTEMS Inc www somfysystems com Canada SOMFY ULC www somfy com India SOMFY INDIA PVT Ltd www somfy com Russia cf Germany SOMFY GmbH www somfy de Cyprus SOMFY MIDDLE EAST www somfy com It...

Page 2: ...ONS POUR L AUTOMATION DES MENUISERIES L SUNGEN F R DIE AUTOMATION FENSTERN OPLOSSINGEN VOOR AUTOMATISCH SLUITEN EN OPENEN SOLUCIONES PARA LAAUTOMACI N DE LOS CERRAMIENTOS USE AND INSTALLATION MANUAL G...

Page 3: ...A04 A05 A06 A01 A02 A03 A A00 B A C E 1 2 3 1 2 3 AF 4 8 x 13 AF 3 5 x 16 M5 x 10...

Page 4: ...A07 A08 A09...

Page 5: ...B04 B05 B06 B01 B02 B03 B B00 2 3 4 AF 3 5 x 16 M5 x 10 AF 4 8 x 22 G A 4 F C 2 3...

Page 6: ...B07 B08 C01 C02 C03 c C00 1 3 AF 4 8 x 13 M5 x 10 E A B C 4 3 H 5 1 4 5 TCCE M4 x 6 AF 4 2 x 9 5...

Page 7: ...C04 C05 C06 C07 C08 C09...

Page 8: ...ENGLISH FRAN AIS DEUTSCH DUTCH ESPA OL 1 2 12 22 32 42...

Page 9: ...m hung applications The position of the threeway switch buttons must be outside the field of action of the moving part of the window Do not let children play with fixed controls wall controls and keep...

Page 10: ...and injury to the operator In case of installation of the actuator on a window wich is installed at less then 2 5 meters from ground level or other level access the actuator must be controlled esclusi...

Page 11: ...nect the actuator from the power supply 2 Immediately contact SOMFY Technical Sales Department If the window does not close correctly proceed as follows 1 Remove safety split pin E 2 Use the control p...

Page 12: ...h two limit switches that stop opening and closing at the beginning and the end of the stroke It is therefore necessary to ensure that the internal microswitches disconnect the power supply to the mot...

Page 13: ...acket C onto the spacer using the screws 4 supplied Fix the actuator in this position by using an Allen wrench not supplied to tighten the hexagonal head dowels 3 on the back of the bracket Align chai...

Page 14: ...r the installation of changeover switches with mid OFF position with man present control or equivalent The position of the three way switch buttons must be outside the field of action of the moving pa...

Page 15: ...mid OFF position a opens b closes C Bipolar main power supply switch with minimum contact opening of 3 mm Linkeo 2 D01 D02 8 WIRING DIAGRAMS LINEKO 2 230V AC Power supply voltage shown on the rating...

Page 16: ...the electric load and length of the line B Bipolar switch with mid OFF position a opens b closes D03 D04 WIRING DIAGRAMS LINKEO 2 24V DC CONDUCTORS COMPARATIVE TABLE LINKEO 2 24V DC COLOUR NUMBER SIGN...

Page 17: ...the end position is reached open closed open completely extended chain closed completely retracted chain Available opening strokes between 200 and 250 mm Actuator ratings plate SPECIFICATIONS Linkeo 2...

Page 18: ...ERRORS TO BE AVOIDED Assembly not aligned with actuator Double control switch is not interlocked SPECIFICATIONS Linkeo 2 11...

Reviews: