background image

Installer Mode

This mode allows for

final programming

readjusting of the DOWN limit only and

5

IMPORTANT
If the installation is made up of several OREA RTS motors, only one OREA RTS motor must be powered during programming.
This will avoid interference with the first programming of each OREA RTS motor. If several motors are connected on the same
power supply please

6.5 "Resetting motors back to USER MODE".

refer to the Warning note in Section

The application jogs briefly UP/DOWN indicating that the UP and DOWN position
have been memorized in the motor. The motor is now in
and operates in a momentary fashion

INSTALLER MODE

.

Record the UP and DOWN
positions by pressing the
STOP button for more than
2 seconds. The setting of the
end limits is now completed.

Stop the motor at the desired DOWN limit

> 2 seconds

To set the DOWN limit, press
the STOP and DOWN buttons
for more than 2 seconds. Release
the buttons once the end-product
begins to move, and be prepared
to stop it at its DOWN limit.

> 2 seconds

IMPORTANT!

> 2 seconds

To set the UP limit, press the
STOP and UP buttons for more
than 2 seconds. Release the
buttons once the product begins
to move.

STOP

d

c

The awning goes up and reaches the completely
closed position of the box.

The end-product moves towards the DOWN limit.

*If the INSTALLER MODE directly follows FACTORY MODE, with no power interruption to the motor, go directly to Section 5.2

HELPFUL HINTS:

1. Once the end limits are confirmed during FACTORY MODE, it is possible to delete the limits and start over at the beginning.

- Just press UP & DOWN simultaneously for 2 sec. until the motor jogs. This deletes the limits and starts you at the

beginning of Factory Mode.

2. If the OREA motor is still powered after confirming the limits, only this activated transmitter/channel can be recorded by

pressing the programming button (this prevents other transmitters from being recorded during factory environments).

3. The only way to record a different transmitter/channel is to perform a single power cut in INSTALLER MODE (which is right

after both limits have been confirmed). Then press any transmitter button (UP, STOP or DOWN)

to activate

this transmitter's address into the memory of the motor. The first transmitter you activate will only respond, unless you
perform another single power cut. Then press the programming button to record this new transmitter/channel.

independently

4) Adjust the end product to the up position, approximately 4 inches before the cassette awning is completely closed.

This distance is required for the motor to activate the low torque mode prior to closing and to establish a reference
starting point.

5) Setting of the END LIMITS

Read the complete limit setting procedure before proceeding with setting the UP and DOWN limits.

If necessary, adjust the
correct down position
using the UP and DOWN
buttons.

Remember the

motor responds to the
transmitter in a
momentary fashion.

Always start at
the upper
reference point

4 in.

a

b

Summary of Contents for Orea RTS

Page 1: ...ld occur Do not proceed until proper operation of the transmitter is verified H The OREA RTS motor must be installed in the tube required for the particular application because the electronic speed variance detection will not allow the motor to turn if the crown does not rotate 120 VAC 60 Hz The Master Channel on a 4 channel transmitter can be used as an additional individual channel for a total o...

Page 2: ...ble should not act as a direct conduit for the water to enter the head of the motor form drip loops ANTENNA HOOD If the installation is made up of several RTS motors only one RTS motor must be powered during programming All other motors must be disconnected This will avoid interferences during the initial programming of each motor The mounting distance between 2 motor heads should not be less than...

Page 3: ...irectly to Section 5 2 HELPFUL HINTS 1 Once the end limits are confirmed during FACTORY MODE it is possible to delete the limits and start over at the beginning Just press UP DOWN simultaneously for 2 sec until the motor jogs This deletes the limits and starts you at the beginning of Factory Mode 2 If the OREA motor is still powered after confirming the limits only this activated transmitter chann...

Page 4: ... motor is in the END LIMIT SETTING STATE Release it when the end product jogs briefly UP DOWN indicating that the transmitter has been memorized into the motor Press the programming button on the RTS transmitter 1 Provide power to the OREA RTS motor Press UP STOP or DOWN on any transmitter in order to take control of the motor Do not press UP and DOWN simultaneously because this will delete the li...

Page 5: ... enter the programming state USING THE INTERMEDIATE POSITION Manually Automatically Press the intermediate button STOP button when the motor is not in motion When the SOLIRIS RTS sensor reaches the set DAYLIGHT THRESHOLD it gives a DOWN command The end product will move to the intermediate position only if the intermediate position has been programmed Otherwise it will move to the DOWN limit TO DE...

Page 6: ...the OREA RTS motors on the same power line To avoid resetting of non concerned motors press briefly any button of their assigned transmitter UP STOP or DOWN The non concerned motors will return to USER MODE RESETTING MOTORS BACK TO USER MODE Release it after the end product jogs briefly UP DOWN The memory of the receiver is cleared all the previous sensors are erased and the new sensor is recorded...

Page 7: ... to indicate that the double power cut has been recorded The motor is in PROGRAMMING STAT for 2 minutes reset E B RESTORING FACTORY MODE Press and the programming button for more than 7 seconds of the NEW RTS transmitter The end product will jog briefly UP DOWN twice Once after 1 second and again after 7 seconds This indicates the OREA RTS motor has been completely cleared HOLD 5 sec PREVIOUSLY RE...

Reviews: