Release it after the end-product jogs briefly UP/DOWN
indicating that the OREA RTS motor is in a
PROGRAMMING STATE

Release it after the end-product jogs briefly UP/DOWN
indicating that the transmitter has been
memorized or deleted in the OREA RTS motor

First activate the OREA RTS memory by pressing
the programming button for more than 2 sec. of
the transmitter/channel previously recorded in the
motor's memory.

Now, select the transmitter/channel you wish to
memorize in the OREA RTS motor.
Press briefly on the programming button of the
new transmitter you wish to assign or delete.

2) Add or Delete a transmitter/channel in the memory of OREA RTS motor. The procedure is the same for adding or deleting

a transmitter/channel. If the transmitter/channel has not been previously memorized it will be added instead of deleted.

Transmitter

previously

recorded

New

Transmitter

>2 Seconds

Repeat this procedure for each additional transmitter/channel you wish to add or delete. It is not possible to delete the
transmitter/channel used to enter the programming state.

!

!

USING THE INTERMEDIATE POSITION

Manually

Automatically

: Press the intermediate button (STOP button)

when the motor is not in motion

: When the SOLIRIS RTS sensor reaches the

set DAYLIGHT THRESHOLD, it gives a DOWN command. The
end-product will move to the intermediate position only if the
intermediate position has been programmed. Otherwise
it will move to the DOWN limit.

TO DELETE THE INTERMEDIATE POSITION

Reach the intermediate position. Then press on the STOP

button and hold it (approx. 5 sec.) until the end-product
jogs briefly. The IP has been deleted.

Press the STOP button
for more than 5 seconds

1) Intermediate position (IP)

RECORDING THE INTERMEDIATE POSITION

Adjust the intermediate position by using the UP, DOWN, and STOP

button on your control. The OREA motor must be in stop position
before programming.

Release it after the end-product jogs briefly
UP/DOWN indicating that the intermediate
position has been memorized in the motor

>5 Seconds

User Mode

This mode is for operating the motor by the end user

One Intermediate Position (IP) can be programmed into the OREA RTS. No reference point is necessary due to the
electronic limit switch. The IP can be reached from any point between the end limits.

6

IP

Summary of Contents for Orea RTS

Page 1: ...ld occur Do not proceed until proper operation of the transmitter is verified H The OREA RTS motor must be installed in the tube required for the particular application because the electronic speed variance detection will not allow the motor to turn if the crown does not rotate 120 VAC 60 Hz The Master Channel on a 4 channel transmitter can be used as an additional individual channel for a total o...

Page 2: ...ble should not act as a direct conduit for the water to enter the head of the motor form drip loops ANTENNA HOOD If the installation is made up of several RTS motors only one RTS motor must be powered during programming All other motors must be disconnected This will avoid interferences during the initial programming of each motor The mounting distance between 2 motor heads should not be less than...

Page 3: ...irectly to Section 5 2 HELPFUL HINTS 1 Once the end limits are confirmed during FACTORY MODE it is possible to delete the limits and start over at the beginning Just press UP DOWN simultaneously for 2 sec until the motor jogs This deletes the limits and starts you at the beginning of Factory Mode 2 If the OREA motor is still powered after confirming the limits only this activated transmitter chann...

Page 4: ... motor is in the END LIMIT SETTING STATE Release it when the end product jogs briefly UP DOWN indicating that the transmitter has been memorized into the motor Press the programming button on the RTS transmitter 1 Provide power to the OREA RTS motor Press UP STOP or DOWN on any transmitter in order to take control of the motor Do not press UP and DOWN simultaneously because this will delete the li...

Page 5: ... enter the programming state USING THE INTERMEDIATE POSITION Manually Automatically Press the intermediate button STOP button when the motor is not in motion When the SOLIRIS RTS sensor reaches the set DAYLIGHT THRESHOLD it gives a DOWN command The end product will move to the intermediate position only if the intermediate position has been programmed Otherwise it will move to the DOWN limit TO DE...

Page 6: ...the OREA RTS motors on the same power line To avoid resetting of non concerned motors press briefly any button of their assigned transmitter UP STOP or DOWN The non concerned motors will return to USER MODE RESETTING MOTORS BACK TO USER MODE Release it after the end product jogs briefly UP DOWN The memory of the receiver is cleared all the previous sensors are erased and the new sensor is recorded...

Page 7: ... to indicate that the double power cut has been recorded The motor is in PROGRAMMING STAT for 2 minutes reset E B RESTORING FACTORY MODE Press and the programming button for more than 7 seconds of the NEW RTS transmitter The end product will jog briefly UP DOWN twice Once after 1 second and again after 7 seconds This indicates the OREA RTS motor has been completely cleared HOLD 5 sec PREVIOUSLY RE...

Reviews: