4) Resetting the motor's memory (recording a new

transmitter when the original transmitter is lost.)

for 1 second

max.

(with a new transmitter after losing the 1st one)

**A.

Perform a power cut in the following sequence:

1. Power-off - 2 sec. minimum
2. Power-on - 5 to 15 seconds
3. Power-off - 2 sec. minimum
4. Power-on

The end product moves for 5 seconds in one direction,
to indicate that the double power cut has been recorded.
The motor is in a PROGRAMMING STATE for 2 minutes.
Proceed to STEP B or C depending on the desired result.

Press the programming button of the NEW RTS transmitter,

Release it after the end-product jogs briefly UP/DOWN

indicating that the transmitter has erased all previous transmitters
and recorded the NEW one.

Press and

the programming button for more than 7 seconds

of the NEW RTS transmitter. The end-product will jog briefly UP/DOWN
twice. Once after 1 second and again after 7 seconds. This indicates the
OREA RTS motor has been completely cleared.

B. RECORDING A NEW TRANSMITTER

C. RESTORING FACTORY MODE

(after losing the 1st transmitter)

HOLD

>5 sec.

NEW TRANSMITTER

5 seconds

WARNING:

This type of power cut affects all

the OREA RTS motors on the same power line. To
avoid resetting of non-concerned motors, press briefly
any button of their assigned transmitter. (UP, STOP, or
DOWN) The non-concerned motors will return to
USER MODE.

**RESETTING MOTORS BACK TO USER MODE

!

Release it after the end-product jogs briefly UP/DOWN

The memory of the receiver is cleared (all the previous
sensors are erased) and the new sensor is recorded.

Press for more than 7 SECONDS
on the programming button of the
new RTS

.

sensor

-

+

-

+

Release it after the end-product jogs briefly UP/DOWN

If it is a new sensor:
If the sensor was previously recorded:

it will be recorded into the motor.

it will be deleted.

Press BRIEFLY on the programming button
of the RTS

.

sensor

b) Record or delete a sensor

c) Erase all the sensors and record a new one

Transmitter

previously

recorded

-

+

-

+

>7 Seconds

!

Release it after the end-product jogs briefly UP/DOWN
indicating that the OREA RTS motor is in a
PROGRAMMING STATE.

Press the

(for more than

2 seconds) of the RTS transmitter/channel which
is already recorded in the motor.

programming button

3) Add or Delete an EOLIS or SOLIRIS Sensor RTS in the memory of OREA RTS motor

a) Enter the "PROGRAMMING STATE"

>2 Seconds

NOTE: A double power cut cannot be achieved if the motor is

still in FACTORY or INSTALLER mode. First program a
transmitter into the memory of the motor.

Summary of Contents for Orea RTS

Page 1: ...ld occur Do not proceed until proper operation of the transmitter is verified H The OREA RTS motor must be installed in the tube required for the particular application because the electronic speed variance detection will not allow the motor to turn if the crown does not rotate 120 VAC 60 Hz The Master Channel on a 4 channel transmitter can be used as an additional individual channel for a total o...

Page 2: ...ble should not act as a direct conduit for the water to enter the head of the motor form drip loops ANTENNA HOOD If the installation is made up of several RTS motors only one RTS motor must be powered during programming All other motors must be disconnected This will avoid interferences during the initial programming of each motor The mounting distance between 2 motor heads should not be less than...

Page 3: ...irectly to Section 5 2 HELPFUL HINTS 1 Once the end limits are confirmed during FACTORY MODE it is possible to delete the limits and start over at the beginning Just press UP DOWN simultaneously for 2 sec until the motor jogs This deletes the limits and starts you at the beginning of Factory Mode 2 If the OREA motor is still powered after confirming the limits only this activated transmitter chann...

Page 4: ... motor is in the END LIMIT SETTING STATE Release it when the end product jogs briefly UP DOWN indicating that the transmitter has been memorized into the motor Press the programming button on the RTS transmitter 1 Provide power to the OREA RTS motor Press UP STOP or DOWN on any transmitter in order to take control of the motor Do not press UP and DOWN simultaneously because this will delete the li...

Page 5: ... enter the programming state USING THE INTERMEDIATE POSITION Manually Automatically Press the intermediate button STOP button when the motor is not in motion When the SOLIRIS RTS sensor reaches the set DAYLIGHT THRESHOLD it gives a DOWN command The end product will move to the intermediate position only if the intermediate position has been programmed Otherwise it will move to the DOWN limit TO DE...

Page 6: ...the OREA RTS motors on the same power line To avoid resetting of non concerned motors press briefly any button of their assigned transmitter UP STOP or DOWN The non concerned motors will return to USER MODE RESETTING MOTORS BACK TO USER MODE Release it after the end product jogs briefly UP DOWN The memory of the receiver is cleared all the previous sensors are erased and the new sensor is recorded...

Page 7: ... to indicate that the double power cut has been recorded The motor is in PROGRAMMING STAT for 2 minutes reset E B RESTORING FACTORY MODE Press and the programming button for more than 7 seconds of the NEW RTS transmitter The end product will jog briefly UP DOWN twice Once after 1 second and again after 7 seconds This indicates the OREA RTS motor has been completely cleared HOLD 5 sec PREVIOUSLY RE...

Reviews: