Input sockets
COM
common socket for all quantities to be measured and transistor
testing (COM) (negative)
voltage, resistance, capacity, frequency, duty factor and diode
tester input (positive)
current (0 – 400 mA), transistor tester (IN) input (positive)
10 A
current (400 mA – 10 A) input (positive)
Accuracy
Accuracy is ensured for one year after calibration, at an operating tempera-
ture of 18 °C – 28 °C and a relative humidity of 0% – 75%.
FEATURES
Battery saver function
In order to conserve power, the multimeter automatically switches off after
approx. 15 minutes if no measurement is performed or function is changed.
This is indicated by 5 short beeps 1 minute before switching off then the unit
switches off with a beep.
Contact free phase detection (NCV)
Set the dial to the “NCV” position. If the multimeter’s front (indicated by 1 in
figure) is brought close to a live conductor, the multimeter’s light (indicated
by 2 in figure) and buzzer will activate. Precondition for activation: voltage
exceeding 110 V AC RMS.
Note: Do not rely solely on the instrument, as dangerous voltage may still
be present in the conductor being tested even if there is no indication. De
-
tection can depend on the type of socket, the thickness of insulation, RF
interference and other factors, which can falsify the measurement.
DC voltage measurement (
)
Connect the red probe cable to the
socket, and the black one to the
“COM” socket. Set the dial to the DC voltage position. Connect the mea
-
surement probes to the circuit to be measured.
Note: The reading can be unstable, especially in the 400 mV measurement
range, if the probe cable is not connected to the circuit being measured.
Measurement limit
Resolution
Accuracy
400 mV
0.1 mV
±(0.5% 2 digits)
4 V
1 mV
40 V
10 mV
400 V
100 mV
1000 V
1 V
±(0.8% 2 digits)
Input impedance: 10 MΩ
Maximum input voltage: 1000 V DC or 750 V AC RMS
DC measurement (
)
Connect the black probe cable to the “COM” socket. Connect the red probe
cable and set the selector dial according to the current values to be mea
-
sured:
Current to be measured Red probe cable
Dial setting
connection (socket)
0 – 4 mA
4 – 400 mA
0.4 – 10 A
10 A
Use the “FUNC” pushbutton to set the DC (
) function. Interrupt the
circuit whose current is to be measured then connect the probe to the points
to be measured.
Measurement limit
Resolution
Accuracy
400 µA
0.1 µA
±(0.8% 2 digits)
4 mA
1 µA
40 mA
10 µA
400 mA
100 µA
4 A
1 mA
±(2.0% 5 digits)
10 A
10 mA
Overload protection: The F400 mA / 1000 V fuse is at the
socket
while the F10A/500 V fuse is at the “10A” socket.
Max input current:
socket: 400 mA DC or AC RMS; at “10A” socket:
10A DC or AC RMS If the measured current is greater than 5 A, the duration
of continuous measurement should not exceed 10 seconds, and at least 1
minute should elapse between two measurements.
Measurement of AC voltage (
)
Connect the red probe cable to the
socket, and the black one to the
“COM” socket. Set the dial to the AC voltage position. Connect the mea
-
surement probes to the circuit to be measured. Note: The reading can be
unstable, especially in the 400 mV measurement range, if the probe cable is
not connected to the circuit being measured.
Measurement limit
Resolution
Accuracy
400 mV
0.1 mV
±(2% 3 digits)
4 V
1 mV
±(0.8% 2 digits)
40 V
10 mV
400 V
100 mV
750 V
1 V
±(1% 3 digits)
Input impedance: 10 MΩ. Maximum input voltage: 1000 V DC or 750 V AC
RMS. Measuring range: 40 Hz- 400 Hz
Measurement of AC (
)
Connect the black probe cable to the “COM” socket. Connect the red probe
cable and set the selector dial according to the current values to be mea
-
sured:
Current to be measured Red probe cable
Dial setting
connection (socket)
0 – 4 mA
4 – 400 mA
0.4 – 10 A
10 A
Use the “FUNC” pushbutton to set the AC (
) function. Interrupt the
circuit whose current is to be measured then connect the probe to the points
to be measured.
Measurement limit
Resolution
Accuracy
400 µA
0.1 µA
±(1.5% 2 digits)
4 mA
1 µA
40 mA
10 µA
400 mA
100 µA
4 A
1 mA
±(2.5% 5 digits)
10 A
10 mA
Overload protection: The F400 mA / 1000 V fuse is at the
socket while
the F10A/500 V fuse is at the “10A” socket.
Max input current: socket: 400 mA DC or AC RMS; at “10A” socket:
10A DC or AC RMS
If the measured current is greater than 5 A, the duration of continuous
measurement should not exceed 10 seconds, and at least 1 minute should
elapse between two measurements.
Measuring range: 40 Hz – 400 Hz
Frequency measurement
Connect the red probe cable to the
socket, and the black one to the
“COM” socket. Set the dial to the “Hz%” measurement range. Use the “Hz/
DUTY” pushbutton to set the frequency (Hz) function. Connect the mea
-
surement probe to the circuit to be measured.
Note: Frequency measurement only works with automatic measurement
range selection. Do not exceed the input voltage as this will damage the
instrument.
Measurement limit
Resolution
Accuracy
9.999 Hz
0.001 Hz
±(0.5% 2 digits)
99.99 Hz
0.01 Hz
999.9 Hz
0.1 Hz
9.999 kHz
1 Hz
99.99 kHz
10 Hz
999.9 kHz
0.1 kHz
9.999 MHz
1 kHz