• Professional microphone set • Robust, metal handheld microphone • In-

novative,  latest  technology  •  Multifunctional  digital  display  •  Frequency/

channel/battery  status  •  RF  radio  signal  strength  meter  •  AF  audiolevel 

meter • Digital noise filter circuit • 2x100 selectable channels • Scanning for 

best  available  channel  •  Automatic  or  manual  setting  •  Fast  infrared  pair

-

ing  •  Noise-free  ON/OFF  switching  •  2x  symmetrical  XLR  audio  outputs  • 

 

6.3 mm mixed audio output • High-gain BNC antennas • Operating range in 

open field: ~140 m • Operating frequency band: UHF • Can be fitted into rack 

cabinet • Accessories: power adapter, 6.3 mm/6.3 mm audio connection cable, 

fixtures, colour coding rings 

COMMISSIONING

Handheld microphone

The portion located under the display consists of an interwoven metal cylinder and 

a plastic cap. Do not remove the plastic cap separately. Remove the metal cylinder 

together with the cap. After the careful removal of the microphone handle from below 

the display, place two size 

AA

 (1.5V) alkaline batteries into the battery compartment 

observing the marked polarity (the positive end pointing downwards). Replace the 

battery compartment cover. The device is turned ON by a single pressing of the button 

under the display and turned OFF by a longer (~2 seconds long) pressing and holding 

down of the button. On the digital display a battery symbol shows the battery status.

• Replace the batteries when indicated by the battery symbol on the display, or if 

operating range is reduced, or transmission becomes noisy. • Batteries can only be 

replaced by adults. • Do not use batteries of various brands and/or status together. • 

Remove the batteries right away when depleted, or if the device will not be used for a 

longer period. • If any fluids have leaked from the batteries, clean the battery compart

-

ment with a dry cloth wearing protective gloves. • Never open, place into fire or short 

circuit the batteries. • Never charge non-rechargeable batteries. Explosion hazard! • 

Do not use rechargeable battery cells instead of batteries, as the voltage output and 

efficiency of these is significantly lower. • The efficiency of batteries is reduced in cold 

ambient temperatures, thus more frequent replacement may be required.

Receiver

Fit the two antennas into place (

ANT A, ANT B

) on the rear side using the BNC con

-

nectors. Connect the included power adapter to the rear socket, then to the mains 

socket. Connect to an audio amplifier, or mixer, or active soundbox using the mixed 

MIXOUT

 (LINE IN for line level input) or 

BALANCED A + BALANCED B

 (for XLR 

symmetrical microphone input) outputs. Use only one type of connection at a time. 

The device is turned ON by a single pressing of the 

POWER

 button under the display 

and turned OFF by a longer (~2 seconds long) pressing and holding down of the 

button.

• In certain cases, a unique connection cable or adapter may be necessary, depending 

on the external device. • Before switching ON the receiver unit and the amplifier, set 

their volume controls, as well as volume controls 

VOL A, VOL B

 to minimum level.

SETTING, PAIRING, FUNCTIONS

When  the  receiver  and  handheld  microphones  are  turned  ON,  after  a  successful 

automatic pairing, the RF graphic display will indicate both the achievement of a con

-

nection and the field strength. Carefully set VOL A and VOL B controls to the medium 

position and the volume control of the amplifier to a lower position. If connection was 

not achieved, or it is not clear, change to another frequency. Microphones and the 

receiver unit can be paired, and the appropriate channel (frequency) can be selected 

in two ways.
1. AUTOMATIC SETTING: Remove the metal cap of the handheld microphone. Press 

and hold down the 

˅

 button for 2 seconds. The display shows 

SCAN

 and the scanning 

process of all channels from 00-99 can be followed on the display. When the device 

has selected the ideal, noise-free channel for connection, along with the 

IR

 message it 

transmits the respective code of the channel to the handheld microphone and pairing 

is realized. This is successful when the 

UHF

 (IR) sign on the handheld microphone 

points towards the infra LED to the left of the 

POWER

 button. Position the handheld 

microphone close to the front panel of the receiver unit. Pairing is complete, when 

the microphone and the receiver unit displays show the same frequency. Repeat the 

above steps for the second microphone as well.
2. MANUAL SETTING: Press and hold down the 

˄

 button for 2 seconds. The 

CH

 

signal starts flashing on the display. Within 5 seconds, press repeatedly, or press and 

hold down either of the 

˅˄ 

buttons in order to select the desired channel (frequency). 

The setting is stored after 5 seconds. This channel needs to be then transmitted to the 

handheld microphone via the wireless infra connection. In order to do so, remove the 

metal cap of the microphone, and point the 

UHF

 (IR) sign towards the infra LED to 

the left of the 

POWER

 button, while holding it close to the receiver unit. Synchronize 

the two devices using the 

SET

 button. This is successful when the microphone and 

the receiver unit displays show the same frequency. Repeat the above steps for the 

second microphone as well.

If the microphone is turned OFF, the battery status indication disappears and the 

MUTE

 message shows on the receiver unit’s display. Apply this method to mute either 

one of the microphones. 

• 

 It is recommended

 to use 

automatic

 (

SCAN

) channel selection. Otherwise, the op-

erating range may be significantly reduced. When the operating range is exceeded, 

the device automatically mutes the resulting noise (Squelch function).

•  The two devices to be paired should be close to one another. In case of connection 

problems, select another frequency, or turn the microphone and the receiver unit off 

and back on again, or reposition the devices. 

•  The RF display of the receiver unit provides information on the existence of a stable 

radio connection and the signal strength of the connection.

• The AF instrument indicates the level of the audio signal.

• 2x100 channels can be selected (0-99).

•  The battery status of the handheld microphone can also be observed on the display 

of the receiver unit. 

•  Walls, nearby electric appliances and moving bodies can disturb reception, or reduce 

the operating range. In particular mobile phones, Wi-Fi routers, computers or larger 

metal objects.

•  Several microphone sets can be used in the same area, as long as various channels 

are selected for each.

•  A volume set too low results in higher noise, while a volume set too high will result 

in distorted sound. The volume setting of the amplifier and the microphone receiver 

should correspond. Ideal setting also depends on the position of the microphones.

PROTECTION AGAINST UNWANTED RESETTING

Upon the simultaneous pressing and holding down of the 

˅˄

 buttons for 2 seconds, 

the lock symbol appears on the display. This prevents any unwanted pressing of the 

setting buttons, thus the resetting of the device. This function is particularly useful 

when unauthorized persons can also have access to the devices during use. Use the 

same method to deactivate the lock function.

TIPS

•  The antenna of the handheld microphones is located on the bottom. Therefore, avoid 

holding the plastic cap of the microphones as this can suppress transmission.  

• Do not move the microphone in the hands as it modifies the conditions of reception.

•  Using colour coding labels, the sound engineer can identify and manage each micro

-

phone even from a distance. 

•  Frequencies around 800MHz may be noisier if, in the given geographical region, it is 

also used by mobile phone stations. 

•  Avoid the presence of powered mobile phones, Bluetooth devices, television sets, 

computers, Wi-Fi routers or other radio frequency equipment in the surroundings, as 

these can disturb reception.

•  The receiver unit should be at least 1 m above ground level. Do not mount the re

-

ceiver on walls, wall-mounted shelves, as this significantly deteriorates the conditions 

of reception.

•  If the microphone is positioned in front of or nearby the loudspeaker, pop noise may 

be generated, which can damage the loudspeakers. It is best to place the micro

-

phone behind the soundbox. Increase the volume carefully during commissioning.  

TROUBLESHOOTING

If there is no sound reception, or sound reception is noisy, check whether

- connection is according to instructions

- supply voltage is present and batteries are good

- the cables are undamaged

- amplifier settings are correct 

- recommended distance was exceeded

- any nearby electric appliances are causing interference

- antennas are set vertically

- the plastic cap is covered

CLEANING

Before cleaning disconnect power supply by switching the device OFF and removing 

the plug from the charger. Use a soft, dry cleaning cloth. Avoid the use of any aggres

-

sive detergents and liquids. 

WIRELESS MICROPHONE SET

Summary of Contents for MVN 910

Page 1: ...pou it uputa za uporabu MVN 910 EN Safety and maintenance H Biztons g s karbantart s SK Bezpe nos a dr ba RO Siguran i ntre inere SRB MNE Bezbednost i odr avanje CZ Bezpe nost a dr ba HR BIH Sigurnost...

Page 2: ...s t s SET p rovanie conectare SET 6 ON OFF be ki za vypn pornit oprit 7 adaptor adapter adapt r adaptor 8 antenna antenna ant na anten 9 outputA B kimenetA B v stupA B ie ireA B 10 mixed output k z s...

Page 3: ...vypn blocare sunet da nu EN H SK RO a cartridge kapszula kazeta capsul b display kijelz displej ecran c ON OFF be ki za vypn pornit oprit d batt cover elemtart puzdro na bat rie suport baterii SRB MN...

Page 4: ...rpet door mat etc With consideration to the presence of supply voltage observe the general rules of contact protection Never touch the device or the power adapter with wet hands Only connect to double...

Page 5: ...kih zhat legyen gy vezesse a csatlakoz k belt hogy az v letlen l ne h z dhasson ki illetve ne botolhasson meg benne senki Ne vezesse a csatlakoz k belt sz nyeg l bt rl stb alatt A h l zati fesz lts g...

Page 6: ...e Pr stroj umiestnite tak aby jeho z str ka bola ahko pr stupn a ovl date n Dbajte na umiestnenie pripojovacieho k bla aby sa n hodou nevytiahol zo siete alebo aby sa o k bel nikto nepotkol Pripojovac...

Page 7: ...a fel nc t fi a cablului de alimentare s fie accesibil i u or de ndep rtat din priz Conduce i cablurile n a a fel nc t s nu se decupleze accidental i nimeni s nu se mpiedice de acestea Nu conduce i c...

Page 8: ...aj tako postavite da priklju ni kabel uvek bude lako dostupan i da ne smeta nogama Priklju ni kabel ne sprovodite ispod tepiha Zbog prisustva mre nog napona dr ite se standardnih mera za tite Vla nim...

Page 9: ...Nap jec kabel pokl dejte tak aby nebylo mo n jeho n hodn odpojen ze z suvky ve zdi respektive abyste zabr nili n hodn mu zakopnut o kabel Nap jec kabel nepokl dejte pod koberec roho ku apod Z d vodu...

Page 10: ...kabel za napajanje tako da se sprije i da se slu ajno izvu e ili da se spotaknete o njega Ne postavljajte kabel za napajanje ispod tepiha vrata i sl Zbog prisutnosti mre nog napona pona ajte se u skl...

Page 11: ...one and the receiver unit displays show the same frequency Repeat the above steps for the second microphone as well 2 MANUAL SETTING Press and hold down the button for 2 seconds The CH signal starts f...

Page 12: ...A p ros t s befejez d tt ha a mikrofon s a vev egys g kijelz je azonos frekvenci t mutat Ism telje meg a m sodik mikrofonnal is 2 MANU LIS Tartsa nyomva a gombot 2 m sodpercig A kijelz n villogni kezd...

Page 13: ...rij ma a P rovanie je dokon en ke na displeji mikrof nu a prij ma a s zobrazen rovnak frekvencie Tento postup zopakujte aj s druh m mikrof nom 2 MANU LNE Podr te stla en tla idlo 2 sekundy Na displeji...

Page 14: ...ep ie afi eaz aceea i frecven Repeta i procedura de mai sus i cu cel lalt microfon 2 MANUAL ine i ap sat butonul timp de 2 secunde Pe ecran va clipi textul CH n decurs de 5 secunde ap sa i sau ine i a...

Page 15: ...e prednjoj strani prijemnika Uparenje je zavr eno ako na displeju prijemnika i mikrofona bude pisala ista frekvencija Proces ponovite i sa drugim mikrofonom 2 MANUALNO Dr ite pritisnuto 2 sekunde tast...

Page 16: ...en kdy je na displeji mikrofonu a p jmov jednotky vyobrazena stejn frekvence Tento postup zopakujte i na druh m mikrofonu 2 MANU LN Tla tko p idr te stisknut po dobu 2 vte in Na displeji bude blikat n...

Page 17: ...jevo od tipke POWER Postavite ru ni mikrofon blizu prednje plo e prijemnika Uparivanje je dovr eno kada mikrofon i prijemnik prika u istu frekvenciju Ponovite gornje korake i za drugi mikrofon 2 RU NO...

Page 18: ...x 265 mm Weight 2x 320 g Voltage pri 100 240 V 50 60 Hz Power On StdBy 2 5 W 0 2 W Voltage sec 12 0 V Current sec 1 0A Cable lenght 1 8 m Polarity Antenna BNC 2x 260 mm 50 Oscillation PLL synthesized...

Page 19: ...stupn nap tie Tensiune de intrare Ulazni napon Vstupn nap t Ulazni napon 100 240 V Input AC frequency Bemen v lt ram frekvenci ja Frekvencia vstupn ho striedav ho pr du Frecven a c a de intrare Frekve...

Page 20: ...rghe Marinescu nr 2 Cod po tal 400337 Tel 40 264 406 488 Fax 40 264 406 489 www somogyi ro Produc tor Somogyi Elektronic Kft Uvoznik za SRB ELEMENTA d o o Jovana Miki a 56 24000 Subotica Srbija Tel 38...

Reviews: