Installing the BPS-1 Cabinet In New Construction 

1. Determine the location for the

Architectural Series panel bracket/
grille and install it according to
its instruction manual.

2. Determine the location for the

BPS -1 cabinet. The minimum
required mounting area is 11”
(279mm) W x 9

1

/

8

” (232mm) H x

53¼” (1353mm) D.

I M P O R TA N T :   T

H E

C E N T E R

O F

P

A N E L

B

R A C K E T

S

S P E A K E R

O P E N

-

I N G

S H O U L D

B E

A P P R O X I M AT E L Y

12” 

F R O M V E N T T U B E E N D O F

BPS-1

C A B I N E T

(

S E E

F

I G U R E

2 ) .

M

A I N TA I N I N G

T H E

V E N T

T U B E

S

P R O P E R L E N G T H I S I N T E G R A L T O T H E

B P S - 1 ’

S A C O U S T I C P E R F O R M A N C E

.   L

E N G T H E N I N G O R S H O R T E N I N G T H E V E N T T U B E T O F I T A D I F F E R E N T

D I S TA N C E W I L L A D V E R S E L Y A F F E C T T H E

B P S - 1 ’

S P E R F O R M A N C E

.  

2. Attach the included Mounting Hole Drilling Template to the ceiling joist at the BPS-1 mounting 

location (see 

Figure 3

). Make sure that the template is placed high enough so the BPS-1 cabinet will

not contact the ceiling material after installation. (Contact can cause buzzing during operation.)

3. Drill eight 

5

/

16

" holes through the joist at the locations indicated on the Drilling Template (see 

Figure 3)

.

4. Screw the two Temporary Installation Brackets across the underside of the joist bay at the locations

indicated on the Drilling Template (see 

Figure 4

). 

B6R

Sonance Architectural Series

5/8”

DR

YW

ALL

WWW

.SONANCE.COM

800.582.7777

12”

Joists

BPS-1 Cabinet

Panel Bracket

Figure 2: Positioning the BPS-1 Relative to the Panel Bracket

(Note: Vent tube not shown for clarity)

WA R N I N G

D O   N O T   AT TA C H   T H E   B P S - 1   T O   A N   I - J O I S T   T H AT   H A S   N O T   B E E N   A D E Q U AT E LY   B R A C E D .
D O I N G   S O   C A N   C A U S E   C O L L A P S E ,   R E S U LT I N G   I N   I N J U RY   O R   D E AT H .   C O N S U LT   W I T H   T H E
J O B ’ S   G E N E R A L   C O N T R A C T O R   B E F O R E   AT TA C H I N G   T H E   B P S - 1   T O   A N   I - J O I S T.

Temporary

Brackets

Joists

Figure 4: Attaching the Temporary Brackets 

to the Joists (16” spacing shown)

Drill Holes for
5/16” Lag Screws

Drilling

Template

Figure 3: Drilling Holes For the Lag Screws

Sonance Architectural Series

®

BPS -1 IN-CEILING SUBWOOFER
I N S T A L L A T I O N   M A N U A L

Summary of Contents for BPS-1

Page 1: ... heavily flared to minimize port noise during high volume passages The 8 woofer driver features a felted paper cone with a rubber surround and Kapton voice coil former that provide years of reliable high power operation This allows the BPS 1 to be installed in a location that will have limited or no access The very efficient 4th order bandpass enclosure produces high output over the subwoofer s en...

Page 2: ... Make sure that the template is placed high enough so the BPS 1 cabinet will not contact the ceiling material after installation Contact can cause buzzing during operation 3 Drill eight 5 16 holes through the joist at the locations indicated on the Drilling Template see Figure 3 4 Screw the two Temporary Installation Brackets across the underside of the joist bay at the locations indicated on the ...

Page 3: ... the longer lag screws for standard joist construction 8 After confirming that the BPS 1 cabinet is securely attached to the joist remove the temporary brackets from the underside of the joists Selecting the Proper Bandpass Connector Sonance has BPS 1 Bandpass Connectors available that mate the BPS 1 to every size round and square Architectural Series panel bracket The Bandpass Connectors provide ...

Page 4: ... tube see Figure 9 4 Insert the Bandpass Connector s neck into the Vent Tube opening see Figure 10 Insert Bandpass Connector Neck Into Vent Tube Fit Clamp Onto Vent Tube Figure 9 Fit the Clamp Onto the Vent Tube Figure 10 Fit the Bandpass Connector Neck Into the Vent Tube Page 4 of 8 B6R Sonance Architectural Series 5 8 DRYWALL WWW SONANCE COM 800 582 7777 Remove Screws Figure 7 Remove Panel Brack...

Page 5: ... I N G US E O F A N Y O T H E R P O W E R A M P L I F I E R W I T H T H E BPS 1 C O U L D R E S U LT I N D A M A G E T O T H E W O O F E R A N D W I L L V O I D T H E BPS 1 S WA R R A N T Y 1 Run the speaker wire from the A150 amplifier to the BPS 1 cabinet NOT E RE F E R TO T H E A150 I N S T R U C T I O N M A N U A L F O R I N F O R M AT I O N A B O U T A M P L I F I E R C O N N E C T I O N S 2 ...

Page 6: ...nd painted NOT E FO R PA I N T I N G I N F O R M AT I O N R E F E R TO T H E I N S T R U C T I O N M A N UA L I N C LU D E D W I T H T H E AR C H I T E C T U R A L FI N I S H CO M P O N E N T 1 The foam tape covered rim on the back of the Finish Component inserts into the groove around the outer edge of the Bandpass Connector See Figure 14 2 Insert about half of the Architectural Finish Component ...

Page 7: ... the ceiling material The BPS 1 cabinet weighs 46 lbs Use the supplied drilling template to determine the locations of the mounting holes on the joist NOT E MA K E S U R E T H E H O L E S A R E H I G H E N O U G H O N T H E J O I S T S O T H AT T H E W O O F E R C A B I N E T W I L L N OT C O N TAC T T H E C E I L I N G M AT E R I A L CO N TAC T W I T H T H E C E I L I N G M AT E R I A L C A N C A...

Page 8: ...is warranty statement gives you specific legal rights and you may have other rights which vary from state to state Some states do not allow the exclusion of implied warranties or limitations of remedies so the above exclusions and limitations may not apply If your state does not allow disclaimer of implied warranties the duration of such implied warranties is limited to the period of Sonance s exp...

Reviews: