Lodestar AHRS
Operation Manual
Document Ref: UM-8084-107-A6
Issue: A – Rev 6
© Sonardyne International Limited 2013
30
6.7 Analogue Output Tab
This tab allows the configuration of analogue outputs from the Lodestar.
Analogue
port settings
The output for each pin in the analogue port can be configured on the analogue
port tab, as shown in Figure 22.
Figure 22 – Analogue Port Tab
The analogue output can be enabled or disabled using the ‘Analogue Output’
check box.
The options available for output on each analogue pin are as follows:
Table 2 – Analogue Port output options
Option
Purpose
PITCH
degrees, bow up
ROLL
degrees, starboard down
YAW
[-180... +180] degrees
HDG
Quadrature Phase Signal SIN|COS
HEAVE
Heave, metres
VZ
Velocity in the Navigation Frame, m/s
The voltage scale for each pin can be set from 0-10 volts. A remote point can be
specified for each analogue output pin.
After setting the analogue output, press the ‘Apply’ button on the main application
window to save the configuration to the Lodestar.