Regulation scale:.....................................
from 5 to 35°C
Floor probe scale:...............................
from -30 to +80°C
Ambient temperaure:..................
Tmin. 0°C, Tmax. 40°C
Storage temperature:.............................
maximum 50°C
1,5V Alkaline battery (2 pcs):........................
LR03 (AAA)
Low battery indicator:......................................
Battery duration:.....................................
1,5 year, aprox
Breakage power (contacts):.......................
8(3)A 250Vac
2
Maximum cable to connect:..............................
1,5mm
Type wiring:.......................................................
H-05V-K
Control degree protection:......................................
IP20
Probe degree protection:.........................................
IP67
Degree pollution:..........................................................
2
Software:.............................................................
Class A
Action type:...............................................................
1.B
Homologated:.............................................................
CE
Net weight (with batteries & probe):.....................
207 g
Gross weight:.........................................................
230 g
..............
Installation
4
5
2
1
Batteries replacement
Open the battery compartment cover and insert
two LR03 AAA 1.5V batteries. Make sure the
positive and negative ends are facing the correct
direction, as shown picture of side & always
introducing them as indicated. The display shows
for 2 seconds the program version and then pass to
set the internal clock.
Very Important: Don´t use rechargeables batteries
Energy Control
Technical data
Measures mm
Electrical drawing
Specifications
3
20
80
100
Siesta
Probe
Ø6
40
Cable
PVC L= 3 m
Sheat
Aisi 304
1
2
NO C
3
NC
Probe
>
3