CMM-40
– USER MANUAL
70
Frequency measurement (electrical)
Range
Resolution
Basic uncertainty
40,00Hz ...
10,000kHz
0,01Hz ... 0,001kHz
0,5 % m.v.
Sensitivity: 1Vrms
Duty cycle measurement
Range
Resolution
Basic uncertainty
0,10 ... 99,0%
0,01%
(1,2 % m.v. + 2 digits)
Pulse width: 100µs - 100ms, Frequency: 5Hz to 150kHz
Temperature measurement
Range
Resolution
Basic uncertainty
-50.0…1200,0
C
0,1
C
± (1% m.v. + 2,5
C)
-58.0…2192,0
F
0,1
F
± (1% m.v. + 4,5
F)
* probe accuracy not included
4-20mA% loop measurement
Range
Resolution
Basic uncertainty
-25,00 ... 125,00%
0,01%
50 digits
0mA=-25%, 4mA=0%, 20mA=100%, 24mA=125%
Other technical data
a)
Measurement category in acc. with EN 61010-1 ..................................III 1000V
b)
Ingress protection in acc. with EN 60529 ..................................................... IP67
c)
Pollution degree ................................................................................................. 2
d)
Power supply ............................................................................... one 9V battery
e)
Diode test.......................................................................... I=0,9mA, U
0
=2,8V DC
f)
Continuity test ............................................. I<0,35mA, sound signal for R<35Ω
g)
Overrange indication ..................................................................... OL displayed
Summary of Contents for CMM-40
Page 1: ...INSTRUKCJA OBS UGI 1 USER MANUAL 39 MANUAL DE USO 73 CMM 40 v1 6 19 10 2018...
Page 2: ......
Page 3: ...1 INSTRUKCJA OBS UGI MULTIMETR PRZEMYS OWY CMM 40 Wersja 1 6 19 10 2018...
Page 41: ...39 USER MANUAL INDUSTRIAL MULTIMETER CMM 40 Version 1 6 19 10 2018...
Page 75: ...73 MANUAL DE USO MULT METRO INDUSTRIAL CMM 40 Versi n 1 6 19 10 2018...
Page 111: ......
Page 112: ......