DIT-500
– USER MANUAL
36
Note: Measurement considerations
Holding the meter by its handle, point the IR Sensor toward the
object whose temperature is to be measured. The meter automati-
cally compensates for temperature deviations from ambient tem-
perature. Keep in mind that it will take up to 30 minutes to adjust to
wide ambient temperatures are to be measured followed by high
temperature measurements.
Some time (several minutes) is required after the low (and be-
fore the high) temperature measurements are made. This is a result
of the cooling process, which must take place for the IR sensor.
6 Functional design
6.1
Functionality
In the measuring time, pressing MODE keys to display MAX
value, MIN value, DIF value , AVG value or LOG value.
In the measuring time, if the Type K thermocouple is not
connected, you can adjust
by pressing up/down key.
In the HOLD mode, you can adjust
O
C/
O
F by pressing up/down
key.
You can turn on/off the backlight/laser by pressing
LIGHT/LASER key
①
at any state.
To set values for the high alarm (HAL), low alarm (LAL) and
emissivity (
), press the MODE button until the appropriate code
appears in the display, press the UP and DOWN buttons to
adjust the desired values.
6.2
Functions of MODE button
In the HOLD mode, press the mode button also allows you to
access the set state: MAX, MIN, DIF, AVG or LOG display ->
emissivity (
) -> lock on/off (continuos measuremet) -> high alarm
(HAL) on/off -> HAL adjustment -> low alarm (LAL) on/off -> LAL
adjustment ->
O
C/
O
F.
Each time you press set you advance through the mode cycle.
The diagram shows the sequence of functions in the mode cycle.