EVSE-01 

– USER MANUAL 

10 

5.3 

Control signal CP 

 

Connect the oscilloscope to the CP socket, in order to obtain information about the Pulse-Width 

Modulation (PWM) of the control signal. The signal has a frequency of 1 kHz. Signal duty cycle indi-
cates the status of the charging station or the maximum current that the station can supply. The cur-
rent value can be determined based on the following table, contained in EN 61851-1 standard. 
 

 

 
 
 

 

NOTE! 

 

 

Test CP signal in relation to the PE line.  

 

We  recommend  using  a  battery-powered  portable oscilloscopes  with  isolated  input 
and differential probes that ensure galvanic isolation of the oscilloscope. 

 

If  the  ground  wire  of  the  oscilloscope  is  not  isolated  from  its  casing,  then  before 
connecting  the  oscilloscope,  make  sure  that  the  PE  line  of  the  charging  station  is 
free from dangerous voltage!  

 
 

Summary of Contents for EVSE-01

Page 1: ...4...

Page 2: ...4...

Page 3: ...USER MANUAL ADAPTER FOR TESTING VEHICLE CHARGING STATIONS EVSE 01 FOR MPI METERS SONEL S A Wokulskiego 11 58 100 widnica Poland Version 1 03 10 07 2020...

Page 4: ...ings 5 5 Measurements 6 5 1 Automatic measurements 6 5 2 Manual measurements 8 5 3 Control signal CP 10 6 Cleaning and maintenance 11 7 Storage 11 8 Dismantling and utilisation 11 9 Technical data 11...

Page 5: ...health and safety regula tions and with other relevant fire regulations required during the performance of a particular type of work The adapter must not be used for networks and devices in areas with...

Page 6: ...vidual measurements Perform measurements for all required com binations of settings CP C or D with these settings you can measure the fault loop impedance and test residual current circuit breakers CP...

Page 7: ...ing etc EVSE 01 provides a simulation of situations when the charged object is connected to the charging source via a ca ble with a pre set maximum current PP and the charging cycle is in a mode set o...

Page 8: ...of the meter Select the test required for your meas urements Enter the settings required during the tests For test ZL N ZL L ZL PE RCD protection of phases L1 L2 L3 supplying the charger method for ca...

Page 9: ...work Set CP C or D RCD results from the safety device of the charger Set CP C or D RISO results from the basic insulation of the charger Set CP B After completion of the measurement a summary is displ...

Page 10: ...e test Connect EVSE 01 to the meter If you test 3 phase chargers use banana socket cables If you test 1 phase charger use banana socket cables or WS adapter If you use the WS adapter for testing a 3 p...

Page 11: ...If you test RCD you need to measure L1 PE L2 PE L3 PE If you test RISO you need to measure L1 PE L2 PE L3 PE N PE or L1 L2 L3 N PE Enter settings to EVSE 01 and start the measurement Before and during...

Page 12: ...ation can supply The cur rent value can be determined based on the following table contained in EN 61851 1 standard NOTE Test CP signal in relation to the PE line We recommend using a battery powered...

Page 13: ...onic equipment should be gathered selectively i e it must not be placed with waste of another kind Worn out electronic equipment should be sent to a collection point in accordance with the law of wast...

Page 14: ...tion state E error CP short to PE i socket types measuring sockets L1 L2 L3 N PE 1 phase socket CP signal socket PWM communication j test lead length EVSE 1 m MPI 0 5 m k operating temperature 5 45 C...

Page 15: ...I 530 MPI 525 MPI 520 MPI 502 Auto measurements Automatic three phase measurement via multiplug Visual inspection Fault loop ZL PE ZL N parameters measure ment 6 mA RCD test RCD test AC A F B B EV AC...

Page 16: ...EVSE 01 USER MANUAL 14...

Reviews: