Connecting the cable set to a live service can result in an electric shock.
Precautions:
The connection cable set should never be connected directly to a live service.
The transmitter is capable of outputting potentially lethal voltages.
Precautions:
Care should be taken when handling exposed or non-insulated connections including;
the connection cables sets, the Earth Pin and the connection to the service.
Notify others who may be working on or around the service.
The transmitter is capable of outputting potentially lethal voltages.
Precautions:
Care should be taken when using the maximum power output level.
•
Ensure there are no services below the ground when using the earth pin. Use the Locator
in advance.
•
The black cable can be connected to other metallic structures which go into the ground.
•
In dry conditions it may be necessary to add water around the earth point to get a good
connection.
•
Examine connection points and remove contamination if a continuous audible output is
not achieved.
•
An extension cable is available to extend the red or black cable sets.
Danger
Warning
Warning
SONEL Locator & Transmitter, LKZ-1000
34
Summary of Contents for LKZ-1000
Page 1: ...USER MANUAL v2 2 4 03 2020 ...
Page 27: ...SONEL Locator Transmitter How to Use the Locator 27 ...
Page 66: ...SONEL Locator Transmitter LKZ 1000 66 ...
Page 85: ...SONEL Locator Transmitter 85 ...
Page 86: ......
Page 87: ......