LKZ-1500-
LITE ● LKZ-1500 – USER MANUAL
51
Parameter
Line current measurement at operat-
ing frequency
10 mA to 10.0 А
10 mA to 10.0 А
Max. depth indication error for single,
expanded, and direct communication
{[4+0.3h(h+1)]%+0.1 m},
with
h – measured depth
{[4+0.2h(h+1)]%+0.1 m},
with
h – measured depth
Location accuracy for a 2 m deep
single utility
0.1 m
-
SENSOR input voltage measurement
range at operating frequency
-
0.01 mV to 1.70 V
Maximum error limit of voltage meas-
urement
-
±(3% m.v. + 3 digits)
SENSOR input sensitivity at 6 dB
SNR, min. value [mV]
-
0.05
SENSOR input resistance [MΩ]
-
1
Max input power [W]
-
2
Min. continuous operating time at full
battery pack charge in normal condi-
tions [h]
5
5
* Rated for the “Broad peak” method. The signal-noise ratio is 6 dB.
The Receiver provides signal gain adjustment with the step of 6 dB (each step provides doubled
gain).
12.2.2 Other technical data
a) level of protection according to EN 60529 ................................................................................ IP54
b) power supply ................................................... nickel-metal hydride batteries Ni-Mh 6 V/2000 mAh
c) dimensions ...................................................................................................... 700 x 300 x 140 mm
d) weight
▪ LKO-1500-LITE ............................................................................................................ ca. 1.7 kg
▪ LKO-1500 ..................................................................................................................... ca. 1.8 kg
e) operating temperature ................................................................................................... -20...+55
C
f) storage temperature ...................................................................................................... -50...+70
C
g) relative humidity................................................................................................
max. 95% at +30ºС
h) atmospheric pressure .................................................................................... from 600 to 1067 hPa
i)
fiducial temperature .........................................................................................................
+23 ± 2
C
Summary of Contents for LKZ-1500
Page 1: ......
Page 2: ......
Page 18: ...LKZ 1500 LITE LKZ 1500 USER MANUAL 16 Fig 10 LKO 1500 receiver panel...
Page 30: ...LKZ 1500 LITE LKZ 1500 USER MANUAL 28 Fig 25 Locating with Compass line...
Page 57: ...LKZ 1500 LITE LKZ 1500 USER MANUAL 55 NOTES...
Page 58: ...LKZ 1500 LITE LKZ 1500 USER MANUAL 56 NOTES...
Page 59: ......
Page 60: ......