LKZ-1500-
LITE ● LKZ-1500 – USER MANUAL
36
4.7.2.2 Two-man test method
Set the Transmitter to 33k frequency option and set the optimum power.
Two operators should walk in parallel in the same direction while spaced 20 to 30 m. One of the
operators should walk along the perimeter of the surveyed section while holding the Transmitter so
that the transmitter antenna’s centreline is pointing towards that operator. The other operator needs to
walk along the opposite perimeter line while holding the locator and monitoring the variations on the
bar graph (
). The peak signal is detected when the locator is directly above the located utility.
If the targeted utility line carries a strong signal, it is recommended to enable
Compass
Line
to facilitate tracking (Section 4.6.2.4).
Fig. 33 Testing of ground plots without the LKN-1500 Transmitter
Repeat the survey in the same way, by moving in perpendicular to the previous direction.