LKZ-1500-
LITE ● LKZ-1500 – USER MANUAL
6
2
Description of the system
The LKZ-1500 locator system consists of an LKO-1500 receiver and an LKN-1500 transmitter kitted
as follows:
LKZ-1500-LITE
is a kit of LKN-1500 with LKO-1500-LITE;
LKZ-1500
is a kit of LKN-1500 with LKO-1500.
The system allows to track a route of the underground objects like:
Electrical wires and power cables,
Control and telecommunication lines,
Lightning protection and cathodic protection,
water and sewage installations,
heating systems and pre-insulated pipes,
other metal objects that can conduct electricity.
The icon with the meter name is placed next to sections of the text that refer to specific fea-
tures of the device. All other parts of the text relate to all types of the instrument.
3
LKN-1500 transmitter
The transmitter is designed for generating and transmitting signals in the line under study, and to-
gether with the LKO receiver, it allows to locate the track, determine the burial depth of object, as well
as the location of insulation damage, e.g. cables or pipelines. Current output waveform for LKN-1500
is modified sine wave.
The transmitter can cooperate with any LKO receiver that has the same frequency. Transmitters
are powered by integral maintenance-free sealed accumulator. External 12 V 7 Ah DC source is al-
lowed for use to provide the required power.
Supply voltage self-check system of transmitter indicates its reduction in the range from 11.0 to
10.5 V. If the supply voltage drops between 10.0 and 10.5 V, the transmitter shuts down automatical-
ly.
NOTE!
Periodically recharge the battery to the nominal charge voltage. A deep battery drain
(which is less than 10 V) which may occur during prolonged storage will irreversibly dam-
age the battery, which will require its replacement.
The transmitter’s accumulator charging mode is activated automatically when connecting power sup-
ply unit. Transmitter provide accumulator overcharge protection. The transmitter can operate in 3 sig-
nal generation modes:
a) continuous wave generation;
b)
pulsing generation ⅔ (signal generation – 1 sec, pause – 0.5 sec);
c)
pulsing generation ½ (signal generation – 0.5 sec, pause 0.5 sec).
Summary of Contents for LKZ-1500
Page 1: ......
Page 2: ......
Page 18: ...LKZ 1500 LITE LKZ 1500 USER MANUAL 16 Fig 10 LKO 1500 receiver panel...
Page 30: ...LKZ 1500 LITE LKZ 1500 USER MANUAL 28 Fig 25 Locating with Compass line...
Page 57: ...LKZ 1500 LITE LKZ 1500 USER MANUAL 55 NOTES...
Page 58: ...LKZ 1500 LITE LKZ 1500 USER MANUAL 56 NOTES...
Page 59: ......
Page 60: ......