PQM-700 Operating Manual
42
5.5
Methods of parameter‘s averaging
Method of averaging parameter
Parameter
Averaging method
RMS Voltage
RMS
DC voltage
arithmetic average
Frequency
arithmetic average
Crest factor U, I
arithmetic average
Symmetrical components U, I
RMS
Unbalance factor U, I
calculated from average values of symmetrical components
RMS Current
RMS
Active, Reactive, Apparent and
Distortion Power
arithmetic average
Power factor PF
calculated from the averaged power values
cos
arithmetic average
tan
calculated from the averaged power values
THD U, I
calculated as the ratio of the average RMS value of the higher harmonics
to the average RMS value of the fundamental component (for THD-F), or
the ratio of the average of RMS value of higher harmonics to the average
value of RMS value (for THD-R)
Harmonic amplitudes U, I
RMS
The angles between voltage
and current harmonics
arithmetic average
Active and reactive power of
harmonics
arithmetic average
Note:
RMS average value is calculated according to the formula:
𝑅𝑀𝑆 = √
1
𝑁
∑,
𝑖
2
𝑁
𝑖=1
The arithmetic average (AVG) is calculated according to the formula:
𝐴𝑉𝐺 =
1
𝑁
∑,
𝑖
𝑁
𝑖=1
where:
X
i
is subsequent parameter value to be averaged,
N is the number of values to be averaged.