TDR-410 OPERATING MANUAL    version 1.03 

3 minutes

,  

then press 

ESC

 to store setting to memory. 

3.3  Set Contrast from menu display 

Press 

  (SET)  to  move 

  to  Contrast.  Press 

  to  decrease  contrast,  press 

  to  increase 

contrast, then press 

ESC 

to store setting to memory. 

 

3.4  Backlight 

The LCD display is fitted with an electro-luminescent backlight to enable easy viewing under a variety 

of different lighting conditions. The backlight is switched on and off with the key

 

Note:

 When switched on, the backlight will significantly shorten the battery life! 

3.5  Set Velocity of Propagation from menu display 

Velocity of propagation (Vp) may be set as % or speed in micro seconds (

µs). The unit of measure, 

the speed is displayed in (feet or meters), will be determined by the setting selected in section 3.1 

Press 

 (

SET

) to move to displayed unit, press 

 to scroll between 

”V/2 m/µs” or ”Vp %Vc”.  

 

To change the value of the V/2 (or Vp) factor, go one level down (press 

SET

 button 

) so that the 

indicator points to the "........ m/

µs" (or "Vp = ...%").  

Pressing the cursor 

 or 

 to increase / decrease the value of the Vp. 

Press 

ESC 

to store selected setting to memory. 

 
Note:

 Setting the correct Velocity of Propagation value is also possible from Trace Display. 

3.6  How to determine V

p

 Settings 

If the TDR-410 is to be used with a cable type for which the Vp is unknown, this must first be deter-
mined by the setting selected in section 3.5 
1. Take a sample of the cable at least 10m or 30 ft long (as long as possible). 
2. Measure the actual length of cable using a rule or tape measure or some other reliable method. 
3. Connect the TDR-410 and adjust the Vp setting such that the tester gives a correct reading of the 
sample length, (refer to section 4.1 Setting cable parameters). 

Summary of Contents for TDR-410

Page 1: ......

Page 2: ......

Page 3: ...TDR 410 OPERATING MANUAL version 1 03 1 OPERATING MANUAL TDR 410 TDR CABLE FAULT LOCATOR SONEL S A Wokulskiego 11 58 100 widnica Poland Version 1 03 08 09 2017...

Page 4: ...having purchased our measuring instrument TDR 410 is a modern measuring device which is easy and safe to use Please acquaint yourself with the present manual in order to avoid measuring errors and pr...

Page 5: ...410 9 4 1 SETTING THE FAULT LOCATION 9 4 1 1 Setting Velocity of Propagation Vp 10 4 1 2 Value Impedance Setting Z 10 4 1 3 Auto Fault Location and Manual Fault Location 10 4 1 4 Selecting range scale...

Page 6: ...TDR 410 OPERATING MANUAL version 1 03 4 15 ACCESSORIES 19 16 MANUFACTURER 19...

Page 7: ...ted conduc tors The TDR 410 has impedance matched circuits for 25 50 75 and 100 ohms and with velocity of propagation settings from 1 99 or the equivalent in feet or meters micro second will cover the...

Page 8: ...tinuity in the studied area based on Vp values select ed by a user and and measured the course time of the pulse 3 Preparing the TDR 410 for use Press button to power the tester the following screen w...

Page 9: ...measure feet or meters Press or to scroll between feet and meters Press ESC to store selected setting in memory Note When unit of measure has been selected this will automatically change the V 2 figu...

Page 10: ...ting selected in section 3 1 Press SET to move to displayed unit press to scroll between V 2 m s or Vp Vc To change the value of the V 2 or Vp factor go one level down press SET button so that the ind...

Page 11: ...splay and select TDR pressing the cursor or press START The following screen will be displayed 1 Vp setting 2 Impedance setting Z 3 Manual Auto Fault Location 4 Range scale 5 Battery condition indicat...

Page 12: ...s ESC to store set tings 4 1 3 Auto Fault Location and Manual Fault Location The TDR 410 may be used in auto or manual fault location modes Use SET button to scroll to displayed setting AFL or MFL use...

Page 13: ...and exit press ESC Note Manual measurement range change is just for MFL mode 4 1 5 Gain settings The TDR 410 has pre set gain for each of its 11 range scales there is in addition to this a user con tr...

Page 14: ...to the two wires of the pair MulticoreCable Connect the clips to any two wires 6 Cable Fault Location Having followed the set up procedures in the preceding sections a typical display showing imped an...

Page 15: ...at the bottom right hand corner 6 2 Accuracy The TDR 410 is able to measure distances to faults and cable lengths to an accuracy of 1 This measurement accuracy is based on the correct value of Vp bei...

Page 16: ...refit the battery compartment cover and refit the two screws 9 Cleaning and maintenance NOTE Apply solely the maintenance methods specified by the manufacturer in this manual The casing of the meter...

Page 17: ...ectric and electronic equipment Before the equipment is sent to a collection point do not dismantle any elements Observe the local regulations concerning disposal of packages worn out batteries and ac...

Page 18: ...er diameter 0 643 m paper outer diameter 0 511 mm paper outer diameter 0 404 mm 0 69 0 68 0 66 0 65 0 68 0 65 0 64 0 63 0 69 0 68 0 66 CCTV QR PARA III PARA I T TR TX TX10 RG6 RG11 RG59 Times Fiber RG...

Page 19: ...factor for different cable types are only an indication for the user to make swift and calculate the measurement with reasonable accuracy The use of VP allows the highest measurement accuracy calcula...

Page 20: ...Automatic with range Scan Rate 2 scans second or scan held pre set for each range scale Tone Generator 810 1100Hz Battery Life 30 hours continuous scanning Power Supply 6 volts 4 x 1 5 AA Alkaline cel...

Page 21: ...ser manual It is possible to additionally purchase from the manufacturer and distributors the following elements which are not included within the standard accessories voltage separator AS 2 WAADAAS2...

Page 22: ...TDR 410 OPERATING MANUAL version 1 03 20 NOTES...

Page 23: ......

Page 24: ......

Reviews: