TDR-410 OPERATING MANUAL    version 1.03 

1  Introduction 

A time-domain reflectometer (TDR) is an electronic instrument used to characterize and locate faults 
in metallic cables.  
The TDR-410 is a hand held Time Domain Reflectometer with 11-range-scale covering the range 0-
4000  meters,  with  a  7  meter  first  range  scale  and  a  0.5  meter  dead  zone  close  and  far  faults  are 
clearly displayed on its 128x64 pixel back light LiquidCrystalDisplay. 
The Auto Fault Location key will move the cursor directly to the first event or fault, thus  it eliminates 
the  need  to  interpret  visiually  the  form  of  wave.  When  set  in  manual  mode,  the  wave  form  may  be 
scanned  visually  as  on  conventional  TDRs.  In  both  modes  the  user  gains  variably  coverage  of  the 
range  of  default  to  64  db's  used  to  magnify  small  events  identified  on  the  waveform.  The  scan lock 
feature will allow the user to hold the trace for closer examination. 
Designed for identifying and locating faults on all metallic cables with two or more insulated conduc-
tors. The TDR-410 has impedance matched circuits for 25, 50, 75 and 100 ohms and with velocity of 
propagation  settings  from  1-99%  (or  the  equivalent  in  feet  or  meters/micro  second)  will  cover  the 
range of power, data, communication and CCTV cables. 
Housed in a rugged IP54 rated ABS enclosure and weighs only 350 grams (12 ounces), theTDR-410 
is suitable for outside use. 
 

 

 

   

NOTE!  

Only standard and additional accessories for a given device should be used, as listed  

in the "Equipment" section. Use of different accessories can lead to errors in the test  

connection and can introduce additional measurement uncertainties.  

 

 

 

Note:  

Due to continuous development of the meter’s software, the actual appearance of the 

display, in case of some of the functions, may slightly differ from the display presented 

in this operating manual.  

  

 
 

 

Warning:  

 

This instrument meets the safety requirements of IEC 61010-1:1995 

 

TheTDR-410 is designed for use on de-energized circuits only. 

 

Connection to line voltages will damage the instrument and could be 

hazardous to the operator. 

 

This instrument is protected against connection to telecom network voltages 

according to EN 61326-1. 

 

Safety is the responsibility of the operator  

 

 
 

Summary of Contents for TDR-410

Page 1: ......

Page 2: ......

Page 3: ...TDR 410 OPERATING MANUAL version 1 03 1 OPERATING MANUAL TDR 410 TDR CABLE FAULT LOCATOR SONEL S A Wokulskiego 11 58 100 widnica Poland Version 1 03 08 09 2017...

Page 4: ...having purchased our measuring instrument TDR 410 is a modern measuring device which is easy and safe to use Please acquaint yourself with the present manual in order to avoid measuring errors and pr...

Page 5: ...410 9 4 1 SETTING THE FAULT LOCATION 9 4 1 1 Setting Velocity of Propagation Vp 10 4 1 2 Value Impedance Setting Z 10 4 1 3 Auto Fault Location and Manual Fault Location 10 4 1 4 Selecting range scale...

Page 6: ...TDR 410 OPERATING MANUAL version 1 03 4 15 ACCESSORIES 19 16 MANUFACTURER 19...

Page 7: ...ted conduc tors The TDR 410 has impedance matched circuits for 25 50 75 and 100 ohms and with velocity of propagation settings from 1 99 or the equivalent in feet or meters micro second will cover the...

Page 8: ...tinuity in the studied area based on Vp values select ed by a user and and measured the course time of the pulse 3 Preparing the TDR 410 for use Press button to power the tester the following screen w...

Page 9: ...measure feet or meters Press or to scroll between feet and meters Press ESC to store selected setting in memory Note When unit of measure has been selected this will automatically change the V 2 figu...

Page 10: ...ting selected in section 3 1 Press SET to move to displayed unit press to scroll between V 2 m s or Vp Vc To change the value of the V 2 or Vp factor go one level down press SET button so that the ind...

Page 11: ...splay and select TDR pressing the cursor or press START The following screen will be displayed 1 Vp setting 2 Impedance setting Z 3 Manual Auto Fault Location 4 Range scale 5 Battery condition indicat...

Page 12: ...s ESC to store set tings 4 1 3 Auto Fault Location and Manual Fault Location The TDR 410 may be used in auto or manual fault location modes Use SET button to scroll to displayed setting AFL or MFL use...

Page 13: ...and exit press ESC Note Manual measurement range change is just for MFL mode 4 1 5 Gain settings The TDR 410 has pre set gain for each of its 11 range scales there is in addition to this a user con tr...

Page 14: ...to the two wires of the pair MulticoreCable Connect the clips to any two wires 6 Cable Fault Location Having followed the set up procedures in the preceding sections a typical display showing imped an...

Page 15: ...at the bottom right hand corner 6 2 Accuracy The TDR 410 is able to measure distances to faults and cable lengths to an accuracy of 1 This measurement accuracy is based on the correct value of Vp bei...

Page 16: ...refit the battery compartment cover and refit the two screws 9 Cleaning and maintenance NOTE Apply solely the maintenance methods specified by the manufacturer in this manual The casing of the meter...

Page 17: ...ectric and electronic equipment Before the equipment is sent to a collection point do not dismantle any elements Observe the local regulations concerning disposal of packages worn out batteries and ac...

Page 18: ...er diameter 0 643 m paper outer diameter 0 511 mm paper outer diameter 0 404 mm 0 69 0 68 0 66 0 65 0 68 0 65 0 64 0 63 0 69 0 68 0 66 CCTV QR PARA III PARA I T TR TX TX10 RG6 RG11 RG59 Times Fiber RG...

Page 19: ...factor for different cable types are only an indication for the user to make swift and calculate the measurement with reasonable accuracy The use of VP allows the highest measurement accuracy calcula...

Page 20: ...Automatic with range Scan Rate 2 scans second or scan held pre set for each range scale Tone Generator 810 1100Hz Battery Life 30 hours continuous scanning Power Supply 6 volts 4 x 1 5 AA Alkaline cel...

Page 21: ...ser manual It is possible to additionally purchase from the manufacturer and distributors the following elements which are not included within the standard accessories voltage separator AS 2 WAADAAS2...

Page 22: ...TDR 410 OPERATING MANUAL version 1 03 20 NOTES...

Page 23: ......

Page 24: ......

Reviews: