TDR-410 OPERATING MANUAL version 1.03
5
1 Introduction
A time-domain reflectometer (TDR) is an electronic instrument used to characterize and locate faults
in metallic cables.
The TDR-410 is a hand held Time Domain Reflectometer with 11-range-scale covering the range 0-
4000 meters, with a 7 meter first range scale and a 0.5 meter dead zone close and far faults are
clearly displayed on its 128x64 pixel back light LiquidCrystalDisplay.
The Auto Fault Location key will move the cursor directly to the first event or fault, thus it eliminates
the need to interpret visiually the form of wave. When set in manual mode, the wave form may be
scanned visually as on conventional TDRs. In both modes the user gains variably coverage of the
range of default to 64 db's used to magnify small events identified on the waveform. The scan lock
feature will allow the user to hold the trace for closer examination.
Designed for identifying and locating faults on all metallic cables with two or more insulated conduc-
tors. The TDR-410 has impedance matched circuits for 25, 50, 75 and 100 ohms and with velocity of
propagation settings from 1-99% (or the equivalent in feet or meters/micro second) will cover the
range of power, data, communication and CCTV cables.
Housed in a rugged IP54 rated ABS enclosure and weighs only 350 grams (12 ounces), theTDR-410
is suitable for outside use.
NOTE!
Only standard and additional accessories for a given device should be used, as listed
in the "Equipment" section. Use of different accessories can lead to errors in the test
connection and can introduce additional measurement uncertainties.
Note:
Due to continuous development of the meter’s software, the actual appearance of the
display, in case of some of the functions, may slightly differ from the display presented
in this operating manual.
Warning:
This instrument meets the safety requirements of IEC 61010-1:1995
TheTDR-410 is designed for use on de-energized circuits only.
Connection to line voltages will damage the instrument and could be
hazardous to the operator.
This instrument is protected against connection to telecom network voltages
according to EN 61326-1.
Safety is the responsibility of the operator