background image

POWER SUPPLY  P3208

 

DESCRIPTION

Switched  7,5 VA power supply unit.
Designed to supply installations with 1 tuner and 1 stereo control; or for 
installations with 2 mono controls.

It has a permanent connection to network (no switch); we recommend 
installing a specific general swith for the sound installation.

It can be used in every type of installation.

 

GENERAL CHARACTERISTICS

Power supply unit stabilised and regulated.

Connection to network via screw-strips 

230V - 50Hz nominal network voltage.

Output voltage: 15Vdc-0.4 / 7W

Permanent connection to network; cable section <0.75 mm2

Output voltage indication led.

Output protected against shortcuts

Internal fuse for network input protection 

Due to its dimensions, it can be installed in standard box, together with 

a PCB series control.

-

-

-

-

-

-

-

-

-

 

CONNECTION

1. Power supply
2. ON led
3.  Installation supply strips
4.  Network connection strips

TERMINALS:
  L-  Fhase (220/230 V AC)
  N-  Neutral (220/230 V AC)
  2-  Positive - nominal 15 V DC voltage output 0,5 A maximum.
  4-  Negative - Supply and signal earth.

The connection to the 220/230V electricity supply mains will be made 
with 0.75 mm2 section wires and double insulation .

Sonelco

 recommends installing a specific general switch for the sound 

installation. (See installation example).

4FA036801

 

TECHNICAL CHARACTERISTICS

SUPPLY:
 

Operation: 120-264 V AC / 50-60Hz

 

Maximum power: 7,5 VA

 

Output voltage: regulated between 15 V ± 5%

 

Output impedance: 1,5 A 

 

Electronic protection against short-circuits and power surges.

 

Internal fuse for the protection of the power supply.

GENERAL:

 

Maximum dimensions: 49 x 49 x 23 mm.

 

Weight: 40 grs.

1

2

3

4

            IMPORTANT NOTE: Before connecting this apparatus to  
          the mains electricity supply, the Mains Switch of that 
installation should be switched off in order to allow the connec-
tions to be made with safety guarantees. Under no circumstances 
should the source be handled outside its built-in box whilst con-
nected to the alternate current. Please make sure that the earth 
connection is appropriately connected

CONNECTION TO THE NETWORK: 

Screw in the mains supply and 

earth cables to the L, N.

CONNECTION TO THE LINE: 

(See diagramme). Connect the line 2 and 

4 cables following the order indicated in the terminals, making sure to 
fasten them tightly.

START-UP: 

Once the apparatus is installed connect the mains switch of 

the installation in order to supply electricity to the apparatus and check 
that the ON led is lit (2). 

OPERATION INCIDENTS:

Notice: Any handling of the power supply should only be carried out by 
specialised technical personnel and with the mains switch of the audio 
installation disconnected.

A.- LED 2 (ON) DOES NOT LIGHT UP WHEN CONNECTING THE 
MAINS SUPPLY SWITCH

1. Please check the existence of voltage in the network, and the correct 
connection of the network cables.
2. Disconnect strips 2, 4. If the led lights up, the power supply is ok, 
indicating a short-circuit in the supply output (2, 4) and the cabling 
should be revised.

B.- THE LED (ON) flashes.

1. The apparatus enters in a protected mode due to an excessive load 
on its supply terminals. Revise the cabling of the installation and the 
number of modules connected to this power supply. It may be that the 
maximum power that the device can supply is being exceeded. 

Reviews: