Vertical contact toaster
8
P/N 1010926 Rev. B 04/12
Sonic
A.J. Antunes & Co.
1
2
4
5 1 = 1/2"(12.7mm)
2 = 5/8"(15.9mm)
3 = 11/16"(17.5mm)
6 = 7/8"(22.2mm)
THICKNESS
THICKNESS
1
2
3
4
6
6
5
4 = 3/4"(19.1mm)
5 = 13/16"(20.6mm)
3
Operating instructions
OPeratiOn
1
2
3
4
5
1 = 1/2"(12.7mm)
2 = 5/8"(15.9mm)
4 = 3/4"(19.1mm)
5 =13/16"(20.6mm)
6 = 7/8"(22.2mm)
THICKNESS
THICKNESS
1
2
3
4
5
6
6
3 =11/16"(17.5mm)
figure 3. bun thickness compression Knobs
figure 2. toaster controls
Bun thickness
adjustment controls
Bun Landing
area
Power Switch
Hi-Limit Reset
temperature control
(See figure 3)
Reset
Button
Protective
cap
imPOrtant
Verify that the Release Sheet is installed completely
over the Platen (figure 1) before proceeding. failure
to use Release Sheet may cause permanent damage
to the Platen surface that is Not covered by warranty.
1. Set the Bun thickness compression Knobs
(figure 3) to the desired settings for crown and
heels.
2. turn the unit on (figure 2).
3. turn the temperature control (figure 2) to 10.
allow the unit to warm up for 30 minutes before
proceeding.
4. Slide buns across the rotating Butter Wheel
with the cut face down and drop buns into the
Bun feeder (figure 2). cut sides of heel and
crown must face each other and slide against the
Release Sheet.
nOte: after initial run of 4–6 buns, adjust controls
according to the desired finished product.
5. toasted product will drop into the Bun Landing
area (figure 2).
6. test at least 4 buns before putting toaster into ser-
vice. turn temperature control to lower setting
for lighter toasting or to higher setting for darker
toasting.
7 turn the unit off when finished toasting and follow
the daily cleaning procedures.
safety features
Hi-limit reset bUttOn
a Hi-Limit control turns off electrical power to the
Platen if it overheats. to reset this control, allow 10-15
minutes for the unit to cool down. then remove the pro-
tective cap and press the Reset Button located at the
rear of the unit (figure 2).
nOte: if the unit requires continuous resetting,
contact your authorized service agency.
cOnVeyOr interlOcK safety switcH
a conveyor interlock Safety Switch is located on
top of the unit under the Heat Shield (figure 1).
the
conveyor belt chains will nOt rotate unless the
Heat shield is seated properly in place and activat-
ing the conveyor interlock safety switch.
Bun feeder