7-8
(ix)
HANDLE SW LED
LED that is turned ON when the manual handle is used; when the LED is ON,
hoisting operation using electric power is disabled.
When the top cover of the gear box is closed, the LED is OFF.
(x)
+5 V NON-ISO LED
LED that is turned ON when the power of the processor is ON; when the LED is
turned ON, the clinometer is also powered ON.
(xi)
CLINO TX LED
LED that is turned ON when the data is output from the clinometer
(xii)
TB202 connector (contact signal output)
According to the hoisting system condition, the ON/OFF contact signals are output.
Please install the wires for an external rotating beacon (optional), etc., according to
the following diagram.
Be sure that the contact signal output does not exceed the rating shown in the table
below.
Figure: Contact signal output wiring
Table: Contact signal output rating
Rating at contact
30 V DC; 2A
125 V AC; 0.5 V
Fuse (maximum 2A)
+
-
External
power supply
+
-
1
2
SHC-10
TB202