5. Recording
Sonifex Net-Log User Handbook
25
Figure 5.4 Auto Record Mode
Note: If the Net-Log is currently using a program
recording, and you update it with a new program, the
current state of the recording will reflect the new program
state. E.g. if the Net-Log is recording at 4.00pm on a
Monday and a new program is loaded at that time which
has a record stop at 3pm and record start at 5pm on a
Monday, the recording will stop. It will then restart
recording at 5pm.
Saving and Loading Record
Programs
Once you have finished setting up the record programs,
you can make a copy of them on a PC. This can be
particularly useful if you have more than one Net-Log and
you want each machine to follow the same programs.
To save the complete set of record programs for the
connected Net-Log, select File, Save As from the main
menu. A dialog will be displayed allowing you to specify
the location and name of the file that will be used to store
the current program information. Once you have made
these selections, press Save.
To load a previously saved file, select File, Open and then
select the file that contains the required program
information.
Please note, you can only load and save programs whilst
in the record program screen.
Remote Recording
Recording for each channel can also be started remotely
using the 15 Pin D-Type socket found on the rear of the
unit. There are currently four record input pins that can be
assigned as momentary or latched in the Record Remotes
Option screen.
Auto Recording
To use auto recording, you must first make sure that the
auto record mode has been selected, and the auto start
and auto stop parameters have been set as required. See
the Record Format tab of the Options screen – Section 10.
To start auto recording, press the relevant “Record Start”
button. The channel display will show “Waiting for auto
start level…”, and the Net-Log will start recording
automatically when the input audio level rises above the
auto start threshold. The on-screen LED will illuminate red
to indicate when a channel has started recording.
Recording will continue until the input audio level falls
below the auto stop level threshold, at which point the
recording is provisionally ended. The input audio level
must then remain below the stop level threshold for the
period of time set by the stop duration, otherwise
recording will continue.
Once a recording has ended, the length of the new cut is
compared to the auto start duration. If the new cut length
is less than the auto start duration, it will be automatically
deleted.
The process is then repeated the next time the input audio
level rises above the auto start level threshold.
To stop auto recording at any time, press the “Stop”
button.
Summary of Contents for Net-Log
Page 1: ...Sonifex Net Log User Handbook...
Page 6: ...Contents Sonifex Net Log User Handbook...
Page 10: ...License Form Sonifex Net Log User Handbook 4...
Page 16: ...1 Introduction Sonifex Net Log User Handbook 10...
Page 24: ...3 Net Log Set up Installation Sonifex Net Log User Handbook 18...
Page 32: ...5 Recording Sonifex Net Log User Handbook 26...
Page 36: ...6 Playing Downloading Sonifex Net Log Win User Handbook 18...
Page 48: ...9 Serial Control Interface Sonifex Net Log Win User Handbook 30...
Page 56: ...11 The Administrator Sonifex Net Log Win User Handbook 38...
Page 62: ...13 Technical Specification Sonifex Net Log Win User Handbook 44...
Page 64: ...14 Glossary Sonifex Net Log Win User Handbook 46...